Installation, Operating & Maintenance Manual
Dimensional & Clearance Specifications
4
Figure 2: Typical Arrangement. For illustration purposes only.
Refer to all notes below
NOTES for Figure 2:
1. IMPORTANT:
Allow minimum of 36" all around for servicing
2.
All dimensions are approximate. Refer to chart on Page 5.
3.
MM150 Liquid Level Control on CU-2000 and larger models only. CU-360 to CU-1400 have electronic liquid
level controls.
4. IMPORTANT:
Minimum clearance from combustible surfaces.
Refer to Fig. 2 above for legend.
A
1" above top of CU generator
B
Front of CU generator suitable for alcove installation only.
D
1" from rear of CU generator.
E
L
1 " from left side of CU generator.
E
R
16" from right side of CU generator.
F
Type of flooring: "C", suitable for combustible flooring.
Steam Outlet
High Limit
Pressure
Control
Operating
Pressure
Control
Pressure
Gauge
15 PSIG
Safety Valve
MM 150 Liquid
Level Control
(see note 3)
MM 150 Drain Valve
Water Feed Inlet
F
E
L
D
A
B
E
R
Front
Left
Drain Valve
On/Off
Switch
Gauge Glass
Assembly
H
eight
W
idth
L
ength