Installation
VariFrame – Assembly Instructions
page 26
ATTENTION
Make sure that the screws do not penetrate the housing by more than 5 mm.
When screwing the cross beam to the motor housing, make sure that the correct type of screw is
used. Use only the supplied screws!
Observe the maximum torque of 10 Nm for the screws pos. E.
ATTENTION
The lifting columns must be fastened with at least six screw connections between
the frame and the lifting columns. For this purpose, at least three screws must be tightened with the
respective torque on the longitudinal sides of the motor housing. If multiple bore holes are provided,
additional screws may be added.
IMPORTANT
Screws to fasten the lifting columns to the frame are not included in the scope of
delivery.
5.3.2.6
Screw connection of the cross beams – Tabletop size: 1400 mm to 2000 mm x 800 mm
Screw together two overlapping cross beams (pos. A) at four congruent boreholes.
For each screw connection, use a raised head screw (pos. E) and a hex nut (pos. F).
For the alignment of the components, it is helpful to set the distance between the
fixing plates (pos. B) to the edge of the table to 30 mm.
The maximum tightening torque for each screw connection is 7 Nm maximum.
Figure 17 Screwing the cross beams together