9
E N G L I S H •
User's manual
•
Drain water from air compressor tank and
condensation from air lines. See air compres-
sor’s operation manual.
CAUTION
Disconnect the tool from the air
supply before lubricating, installing, removing
or adjusting the tool.
•Lubricate tool, see “Maintenance“ section in
this manual.
•Select the required impact socket. Use exten
-
sion anvil only when needed.
•Connect tool to air hose of recommended
size.
NOTE: The use of a quick connect set makes
connecting easier.
IMPORTANT: The use of air filters and air
line lubricators is recommended.
To use:
•Turn air compressor on and allow air tank to
fill.
•Set the air compressor’s regulator to 90 PSI
(6.2 bars). This tool operates at a maximum 90
PSI (6.2 bar) pressure.
•Set torque regulator to fit the desired setting
to avoid over tightening.
IMPORTANT:
These torque values can vary
depending on the size of the air compressor
and the cubic feet of air the air compressor
delivers.
•Do not use damaged, frayed or deteriorated
air hoses and fitting.
•Depress the trigger to operate tool.
•Release trigger to stop tool.
•Always disconnect air supply when before lu
-
bricating, installing, removing or adjusting the
tool.
•When job is complete, turn the air compressor
off and store as described in the air compressor
operator manual.
•Always use clean, dry air at 90 PSI (6.2 bars)
maximum air pressure. Dust, corrosive fumes
and/or excessive moisture can ruin the internal
components of a pneumatic tool.
•Do not remove any labels. Replace and dam
-
aged label.
•Keep hands, loose clothing and long hair
away from rotating end of tool.
MAINTENANCE
Lubrication
Air tools require regular lubrication through-
out the life of the tool. The air motor and bear-
ing uses compressed air to power the tool. Be
-
cause moisture in compressed air will rust the
air motor, you must lubricate the motor daily.
An inline oiler is recommended.
To lubricate the air motor manually:
•Disconnect the tool from the air supply hold
-
ing it so the air inlet faces up.
•Depress the trigger and place one to two
drops of air tool oil in the air inlet.
•Connect the tool to an air source, cover the
exhaust end with a towel and run for a few
seconds.
•Do not lubricate tools with flammable or vol
-
atile liquids such as kerosene, diesel or jet fuel
TECHNICAL DATA
REQUIRED PRESSURE
MAX PRESSURE
NAILER/ STAPLER CAPACITY
WEIGHT
SHOOT GAUGE
LENGHT STAPLER/NAILER
CROWN
70-100 PSI
120 PSI
100/85 PIECES
1,3 kg (2.9lb)
18 Cal.
3/8”- 1 1/4”
1/4”
CE632 manual.indd 9