DO NOT use an extension cord or plug adapters. These 
actions may result in a fire hazard or electric shock.

DO NOT operate this unit with damaged power wires. If 
the power wires are damaged it must be replaced by the 
manufacturer or a qualified/licensed service technician.

DO NOT use this unit to circulate fluids, solids, gases, or 
any other substance that is not expressly permitted. This 
fan is designed for air ventilation only.

This unit must be connected to a protective earthing 
system prior to operation. DO NOT remove the grounded 
connection while power is being supplied to the fan. 
Doing so presents an electric shock hazard to users and 
service personnel.

All wiring must be in accordance with the National 
Electrical Code, ANSI/NFPA 70 and local electrical codes. 
Electrical installation should be performed by a qualified 
electrician.

Ensure that power is off before installation or performing 
work on the unit.

To reduce the risk of fire or electric shock, do not use this 
unit with any solid-state speed control device.

To reduce risk of injury, it is recommended to mount the 
fan at least 10 feet (3.1 meters) above the floor.

This device is intended for indoor use only and should be 
protected from rain and flooding.

This equipment is not meant for connection to a duct 
system.

A minimum clearance of 36 inches (915 mm) shall be 
provided around the fan intake and 72 inches (1,828 mm) 
around the shroud to ensure proper air flow and servicing. 
After installation, service and maintenance personnel shall 
be able to access the power supply and fan blades.

Prior to installation, care must be taken to ensure the 
structural integrity of the supporting members when 
mounting the fan. Verify the load bearing capacity of any 
mounting surface is rated for the load of the Ventilator. 

8

Summary of Contents for S-DSVF-115V

Page 1: ...DESTRAT VENTILATOR OPERATING AND MAINTENANCE MANUAL surna com Model S DSVF 115V S DSVF 220V September 2020...

Page 2: ...t requirements of the internationally recognized ISO 9001 standard for quality assurance in design development and production The Highest Standards of Manufacturing EN60335 1 Saftey requirements of ho...

Page 3: ...TABLE OF CONTENTS Specifications 5 Warnings 7 Warranty Information 9 Installation Instructions 11 Routine Maintenance 17 Troubleshooting 18 3...

Page 4: ...S DSVF XXXV MODEL CODE NOMENCLATURE S Surna DSVF Destratification Ventilator Fan 115V 115V 1Ph 50 60Hz 220V 220V 1Ph 50 60Hz 4...

Page 5: ...05 mm Weight 22 lbs 9 98 kg Fan Base Diameter 25 71 0 12 in 653 3 mm Mounting Bracket Length1 6 54 in 166 1 mm Mounting Bracket Width 6 06 in 154 mm ELECTRICAL Power Supply 115V 1Ph 50 60Hz 220V 1Ph 5...

Page 6: ...Q D E F G H D K K DIMENSIONAL DRAWINGS FIGURE 1 Dimensional Drawings A B C D E F 12 in 305 mm 5 51 0 12 in 140 3 mm 5 55 0 12 in 141 3 mm 6 54 in 166 1 mm 0 31 in 8 mm 0 31 in 8 mm G H I J K 0 59 in 1...

Page 7: ...anical jurisdictional codes Using the Ventilator in a manner not described in this manual may void unit warranty Prior to providing power to the equipment inspect the area for water spills which may p...

Page 8: ...tion should be performed by a qualified electrician Ensure that power is off before installation or performing work on the unit To reduce the risk of fire or electric shock do not use this unit with a...

Page 9: ...y or warehouse f o b factory or warehouse for US domestic purposes at Company designated shipping point freight allowed to Company s warranty agent s stock location for all non conforming Company manu...

Page 10: ...f the sealed environment ventilation system This fan helps maintain stable air temperatures throughout the facility s environment by pulling hot humid air from the canopy into the terminal unit proces...

Page 11: ...fan and a minimum of 18 inches 457 2 mm of clearance around the fan intake CAUTION Mount with the lowest moving parts at least 10 feet 3 1 meters above floor or grade level All set screws must be chec...

Page 12: ...gram Dimension Specification A Airflow guide B Hanger bracket C Crossbeam D Bolts with washers for mounting E Supportive wire1 F Supportive wire lock G Hanger base TABLE 3 Bracket Parts 1 Recommended...

Page 13: ...Lift bracket to 900 angle 2 Tighten lower bolts on bracket 3 Insert two bolts into the holes secure using washers and nuts provided INSTALLING BRACKET FIGURE 3 Bracket Installation Diagram 1 2 2 3 3 1...

Page 14: ...nimum of 12 in 304 8 mm from ceiling Mount the Destrat Ventilator as high above the fan coil as possible TABLE 4 Mounting MOUNTING FIGURE 4 Mounting Dimensions 1 To acheive optimal effect mount the De...

Page 15: ...ELECTRICAL FIGURE 5 Connection Diagram 1 5...

Page 16: ...Assembly Wires 4 AWG22 S DSVF 115V and S DSVF 220V Control Methods 0 10V V DC PWM Power Output 10V V DC Tach Output 12 Pulse R Duty 20 to 70 Protection Function Over Temperature Over Current Locked Ro...

Page 17: ...WARNING Before performing any maintenance or servicing verify unit is disconnected from power source DO NOT attempt maintenance or repairs unless you are properly qualified to do so CLEANING THE FAN...

Page 18: ...g power wires are wired according to figures 5 8 UNIT NOT PRODUCING ENOUGH AIRFLOW 1 Verify proper power is supplied of 115V or 220V 2 Check that the fan is clean If not perform routine cleaning See r...

Page 19: ...NOTES 1 9...

Page 20: ...surna com 1780 55th Street Boulder CO 80301 303 993 5271 info surna com A P E Information is subject to change without notice...

Reviews: