Dimension
Specification
A
It is reccommended that the Fan shroud be hung a minimum of 6 in (152.4 mm) above the top of any fan coils
B
Minimum clearance of 18 in (457.2 mm) around fan intake.
C
Minimum clearance of 36 in (915 mm) around fan shroud.
D
Fan to be mounted a minimum of 10 ft (3.1 m) above the floor.
E
It is reccommened that the distance between fan coils and lights be kept as minimal as possible.
F
Mount fan coils a minimum of 12 in (304.8 mm) from ceiling. Mount the Destrat Ventilator as high above the fan coil as possible.
TABLE 4: Mounting
MOUNTING
FIGURE 4: Mounting Dimensions
1. To acheive optimal effect, mount
the Destrat Ventilator at the highest
point of the ceiling or as far above all
other equipment as possible.
3. Lights shown in Figure 4 are used
for example purposes only; lighting
method is immaterial to the use of
the Destrat Ventilator.
NOTES:
2. The Destrat Ventilator must be
mounted to a stable structure to avoid
extreme vibration or falling. Common
methods of mounting include unistrut,
angle iron and all thread. DO NOT use
a rope or chain.