CARE AND MAINTENANCE 2
Replacing the Activated
C
arbon
F
ilter
When the second circle on the sensor plate flashes, the Activated carbon filter needs to be replaced.
1.
Stop the operation and unplug the unit.
2.
Open the bottom plate, disconnect the power cord from
UV
-C+
lamp, take off the unit lock.
3.
Take out the used Activated carbon filter and replace with a new one.
4.
After replacing the Activated carbon filter, press the POWER button for 3 seconds to reset the life time.
Replacing the UV
-C+
lamp
When the inner circle on the sensor plate flashes, the UV
-C+
lamp needs to be re
placed
1.
Stop the
e operation and unplug the unit.
2.
Open the bottom plate, disconnect the power cord from UV
-C+
lamp, remove screw and then
twist to
open the UV
-C+
lamp set to take out the used UV
-C+
lamp.
3.
Replace with a new one and put new UV
-C+
lamp back in the unit, close the UV
-C
+
lamp set, re-connect
the
power
cord and put the bottom plate back on
.
4.
Press the POWER button for 3 seconds to reset the indicator light.
Warning
DO NOT reuse or clean the HEPA
-Rx
filter and the Activated carbon filter.
DO NOT clean the HEPA
-Rx
filter, the Activated carbon filter and any other parts with liquid,
especially alcohol, gasoline, paint thinner, etc. It may cause fire!
Never look directly at UV
-C+
lamps. Direct exposure to
the
light can cause temporary or
chronic
damage to your eyesight, or even blindness.
The
Photocatalytic filter is permanent
and
never need
to be
replac
ed
. When there is dust on it,
clean the dust off using a vacuum cleaner dusting brush. Do not wash it in water.
14