During assembly of the helmet and welding filter, or during the replacement of
the protection screens, make sure that all parts are firmly in place thus prevent-
ing any light from entering the helmet. Should there still be any light entering,
repeat the procedure until the problem is eliminated, otherwise the helmet must
not be used for welding. Before placing the new protection screens, always re-
move the protection layers from both sides.
Figure
D.1
Duo AIR HELMET ASSEMBLY
/ AIRMAX - version of Duo helmet with powered air supply system
for combination with certified Airmax
®
set /
Figure
E
If you have purchased the Duo helmet in a combination with the air supply
system, the helmet will be additionaly equiped with airduct and face seal.
JACKSON SAFETY
®
does not except responsibility for the results of a service
performed by anyone other than a JACKSON SAFETY
®
authorised service
agent. Failure to follow this instructions may invalidate the warranty.
LIMITATIONS ON USE
1.
Material of the hood can cause allergic reactions to a sensitive person.
2.
Do not use tempered mineral filters without suitable protection foils.
3.
The welding arc damages unprotected eyes!
4.
The welding arc may burn unprotected skin!
5.
Pay attention to checking the product before use. Do not use, if any part of the
system is damaged.
6.
Do not put the welding hood on hot surface.
7.
Use only within the temperature range of -5 °C to +55 °C.
8.
Never use the hood in the following environments and under the following
conditions:
• If oxygen concentration in the environment is lower than 17 %.
• In oxygen-enriched environments.
• In explosive ambience.
• In environments where the user lacks knowledge about the kind of dangerous
substance and its concentration.
• In environments representing an immediate threat to the life and health.
• If you are not sure, that shade number of your welding filter lens is suitable for your
work.
• Replace protection filter immediately, if it is damaged, or if spatter or scratches
reduce vision.
• The hood does not protect against hard shocks, explosions or corrosive substances.
9.
Move to a secure location and take appropriate measures when any of the following
problems occur while using the hood:
• If you feel significant increase of breathing resistance or any other problems with
breathing.
• If you experience stench or irritation or an unpleasant taste while breathing.
• If you feel unwell or if you experience nausea.
10.
Use certified original filters designed for your powered air purifying respirator only.
Replace filters every time you detect change of odour in supplied air from the
respirator.
11.
Filters designed for capturing solid and liquid particles (particle filters) do not
protect the user against any gases. Filters designed for capturing gases do not
protect the user against any particles. In the workplace contaminated with both
types of pollution, combined filters must be used.
12.
Protection plates, both internal and external, must be used in conjunction with the
auto-darkening filter in order to protect it against permanent damage.
The Duo AIR helmet assembly is similar to that as described in the section HELMET
AND HEADGEAR ASSEMBLY. The Duo
AIR helmet has also airduct (A) and face
seal (B).
4
EN
Summary of Contents for JACKSON SAFETY AIRMAX J7210
Page 2: ...2...
Page 43: ...43...
Page 87: ...H K K A G B F D E E D F C G A I J A 1 2 3 4 a 4 b B 42...