6
PINLOC5000
iPS
USER MANUAL
sureshotlaser.com
DISPLAY LOC
Each time the Power button is pressed, the distance is displayed on screen for 15 seconds,
after which the screen automatically switches off.
UNIT MEASUREMENT CHANGE
The PINLOC 5000iPS can be used to measure distances in metres or yards. Press the Mode
button for 5 seconds to change the unit of measurement display.
AUTOMATIC POWER-SAVE
The PINLOC 5000iPS will automatically switch off after 15 seconds of inactivity.
BATTERY INDICATOR
A battery level warning will appear when the battery is running low. The battery will last
approximately 3,000 actuations. The battery can be replaced by removing the battery
door (see diagram on page 2). Any brand BCR2-3V lithium battery can be used.
ACCURACY
The PINLOC 5000iPS delivers incredible accuracy at +1 or -1 yard. The range is dependent
on the reflectivity of the target. The color, surface, shape and size of the target will affect
reflectivity and the range. For example, red is highly reflective and will give longer range
as opposed to black which is the least reflective color. A shiny surface will also provide
more range than a dull one and likewise, a small target is more difficult to range than a
large target. The angle to which you set your target also affects accuracy. A 90 degree
angle will give you good range while a steep angle will provide limited range. Please note
lighting, rain and fog can also affect accuracy levels, the less light the shorter the unit’s
maximum range.
255