Before you start applying NH3—
Know the wind direction.
Are the hoses in good condition?
Has the expiration date been passed on any hose or other dated component?
Are all fittings clean and free from rust?
Do low-pressure tubes have any leaks?
Are any knives plugged?
Is the pressure relief valve operating correctly?
Does the tank have five gallons of fresh water?
Is PPE available and being worn (goggles, gloves, long-sleeve shirt) ?
Before performing maintenance on the toolbar or equipment—
Put on gloves and goggles
Make sure you have emergency water
Check wind direction and stay upwind
Park away from buildings, livestock, and people
Before servicing, close the valve on the NH3 tank and continue application to bleed the system.
Be sure the tank valve is closed. Turn the Master valve on and leave it on during bleeding.
Disconnect the nurse tank supply hoses.
Open all bleeder valves on cooler and rest of system.
Check any hoses that have a low loop in them
Even after bleeding, slowly and cautiously loosen any fittings to be sure there is no ammonia trapped in-
side.