FIREPLACE INSERT, MODEL 

«

VOLCANO PLUS

 »

 

Tested and certified to ULC S628-M93, UL 1482-1996 standards and EPA 28 
by Intertek Testing Services 

 

 
 
 
 

OWNER’S MANUAL 

- INSTALLATION 

                                           - OPERATION 

 

 
Save These Instructions for Future Reference 

 
 

 

 
Manufactured by: 

 

3594 Jarry East 
Montreal, QC, H1Z 2G4 
Tel: (514) 593-4722 Fax: (514) 593-4424 

www.supremem.com

 

Summary of Contents for VOLCANO PLUS

Page 1: ...LC S628 M93 UL 1482 1996 standards and EPA 28 by Intertek Testing Services OWNER S MANUAL INSTALLATION OPERATION Save These Instructions for Future Reference Manufactured by 3594 Jarry East Montreal Q...

Page 2: ...responsible for any labor costs 3 From the sixth through the twenty fifth year of the limited lifetime warranty SUPREME FIREPLACES INC will provide replacement parts if available at 50 of the retail p...

Page 3: ...ive creosote accumulation However you may add wood every hour or so to maintain a good fire This will reduce the creosote accumulation in your chimney 3 Dry wood burns longer and creates less creosote...

Page 4: ...ation of creosote in the chimney or flue it must be thoroughly cleaned When installing operating and maintaining a solid fuel heater respect basic standards for fire safety The insert is intended only...

Page 5: ...30 to 38 inches the height at the front can be adjusted up to 28 inches and the height at the rear end is 23 inches The hole location for the liner connection can be adjusted as well up to 2 inches P...

Page 6: ...ace 4 FIREBOX INSTALLATION Note To facilitate installation remove the door from the firebox To remove the door start by pulling out the lower pin end until it is removed from its hole Then lower the d...

Page 7: ...for start up or when a new charge of wood is being loaded OPERATION OF THE COMBUSTION AIR CONTROL MECHANISM When starting the fire or when adding a new charge of wood the fireplace needs additional a...

Page 8: ...nd on top of the first set of wood 4 Place one last log directly above the firestarter but with a clearance of 1 3 inches 5 Push the automatic air control handle inwards and pull it back outwards 6 Li...

Page 9: ...a dangerous steam explosion DO NOT USE YOUR FIREPLACE again until the chimney has been inspected by a qualified chimney sweeper or by a fire department FRESH AIR Adequate replacement air is necessary...

Page 10: ...The glass door should be cleaned with a soft cloth using a non abrasive solution such as soap and water if necessary Abrasive cleaners will produce surface scratches and reduce panel transparency and...

Page 11: ...econdary air pipes DOSP2051 Glass Ceramic 5mm 13 63 x 24 25 in WP32 Door handle LR59458 SY Fan KBMC 13BV Fan speed control T O D36T22 Thermo disk DOSP2071 Door Gasket rope 5 8 in x 7 feet DOSP2061 Gla...