Figure 3-42: Mantel Clearance
3.8 Clearances to Combustibles
The clearances below must be respected to ensure safe operation of the unit under normal and extreme
conditions. Failure to follow the information below is a safety hazard and may result in property damage.
Table 3-8: Overall Clearances
Combustible
Clearance
Reference
Side Wall
16
” (41 mm)
Outer edge of fuel door
Side Trim
4
” (10 mm)
Outer edge of fuel door
Ceiling
84
” (214 mm)
Base of unit
The depth of the mantle is measured from the face
of the fireplace door. When the non-combustible wall
is recessed, the depth of the mantle can be
increased by the amount of the recess (see Figure
3-42). Note that a combustible mantel cannot be
installed below the minimum clearance of 51.5
”
(from the bottom of the mantle to the base of the
unit). A non-
combustible mantle doesn’t require a
minimum distance from the fireplace.
Table 3-9: Combustible Mantel Clearances
Maximum
Mantle Depth
Distance from the Base of
the Elegance 42 to the
Bottom of the Mantle
3
” (7.6 mm)
51.5
” (130.8 mm)
5
” (12.7 mm)
53.5
” (135.9 mm)
7
” (17.8 mm)
55.5
” (141 mm)