09
Heatseeker Solar Pool Heating
Installation & User Manual
INSTALLER SETUP
TO ACCESS MENU PRESS ENTER AND SCROLL DOWN TO SYSTEM AND PRESS
THE MODE BUTTON
WARNING PROFESSIONAL ONLY SETTINGS!
SYSTEM SUB-MENU
RESTORE DEFAULTS
Restore back to factory defaults.
RUN
When the roof temperature rises to pool + RUN then the solar will start.
END
When the roof drops below pool + END then the solar will stop.
FRZ?
Anti freeze function, when switched to ON will start the pump when the roof
temperature drops to the selected temperature and operates for 3 minutes every
30 minutes until the roof temperature rises above the selected temperature.
BOIL?
Anti boil function, when switched to ON will start the pump when the roof
temperature rises to the selected temperature and operates for 5 minutes every 15
minutes until the roof temperature rises above the selected temperature. Switched
to OFF and USE PIPE PROTECTION option will be offered.
PIPE PROTECTION
For use when Heatseeker UniPanels® cannot drain down and will require a wetted
roof sensor for this mode.
CAL
Calibrate the pool sensor.
ADDITIONAL INFORMATION
1. If any of the menu items are left unattended for 3 minutes the menu will time out and
automatically save all settings and return to automatic operation.
2. If a sensor fault is detected the controller will display which sensor and what the fault is.
3. Should power be interrupted for any reason, the controller will resume normal operation when
power is restored. All information will have been kept for up to 10 days.
4. If the controller has stopped pumping and is displaying a higher temperature than expected it may
be caused by a pump which is failing to prime, check the pump and if necessary prime the pump as
per the pump manufacturers’ instructions then reset the controller by turning it off/on.
5. Maximum combined rated output load for the 240V socket(s) is 9.98 Amps / 2395 Watts.
6. Degree of protection against moisture: IP33.
7. Store pool chemicals at least 3 metres safely away from all pool equipment.
8. If the power cord is damaged, do not use the controller; return the unit to the supplier for repair.
Summary of Contents for HEATSEEKER
Page 1: ...INSTALLATION USER MANUAL INSTALLATION USER MANUAL...
Page 2: ...jhowell supremeheating com au HeatingAustralian Pools ForOver30Years...
Page 24: ...22 Heatseeker Solar Pool Heating Installation User Manual NOTES...
Page 25: ...23 Heatseeker Solar Pool Heating Installation User Manual...
Page 26: ...24 Heatseeker Solar Pool Heating Installation User Manual...
Page 27: ...25 Heatseeker Solar Pool Heating Installation User Manual...