![SupplyNet Prophet 4000 Series Manual Download Page 8](http://html.mh-extra.com/html/supplynet/prophet-4000-series/prophet-4000-series_manual_1406144008.webp)
Page
8
3.5
Poly Tank Preparation
Please check the following before installation of the Prophet:
•
A 2 inch diameter threaded opening is required for the installation of a Prophet. If the
tank does not have a threaded opening available, a hole must be cut into the top of the
tank. Refer to the procedure below for the installing a plastic bung kit.
•
For Differential Pressure Prophet installations, verify if a mechanical agitation device
exists within the tank, which could damage the sensor.
•
For Ultrasonic Prophet installations, verify no obstructions exist within the tank which
could alter the ultrasonic readings.
3.6
Installing a Plastic Bung Kit
The following tools are required to complete this procedure:
Plastic bag for catching debris
Duct tape
Drill with a 3-inch holesaw bit
2 inch Plastic Bung Kit
1)
Open the manway at the top of the tank.
2)
Open the plastic bag and secure the opening to the approximate center where the hole
will be drilled. The bag will catch any debris created by the holesaw while drilling
the bunghole.
3)
Using the drill and 3-inch holesaw bit, drill thru the plastic tank.
4)
Once the hole is cut, remove the garbage bag. Use care in removing the bag and duct
tape off the inside surface of the tank.
5)
The 2 inch Plastic Bung Kit may now be installed.
The Bung need only be tightened
by hand
. Refer to Figure 3 for proper assembly.
Tank Bung
(typically left hand threads)
Poly Tank with 3 inch hole cut thru
Rubber G asket
Plastic W asher
Plastic Bung Nut
Figure 3
Plastic Bung Kit Installation