37
6.4.3 Static Span Calibration with Chain Weight
Keep the belt weigher running with loading a chain weight for correcting Span Coefficient.
Put a measured chain weight as a continuous and steady load on the belt weigher and then start the
belt weigher.
0
5
[R]
R: 1-99
P110 Cal. Revs
Main Display Interface
【
MENU
】
+
【
▲
】
【
▼
】
: F2 Calibration
【
ENT
】
+
【
▲
】
【
▼
】
:
3 Span Cal.Stat1
【
ENT
】
M
【
ENT
】
R: 0.1-1000.0
P111 ChainWeight
010.
0
[kg/m]
【
MENU
】
: Exit
【
ENT
】
: Save
【
ENT
】
M
NewSpan: 200320
E%: -0.16%
2 Span Cal. Dyn.
OldSpan: 200000
E% = (Display Weight – Input Weight) /
Input Weight × 100%