21
6.2 Main MENU
Main Menu
Second Menu
Description
F1 Setting
1 Scale[Basic]
Basic scale parameters setting.
1+Scale[Extra]
Extra scale parameters setting.
2 Control[Basic]
Basic feeding control parameters setting.
2+Control[Extra]
Extra feeding and batching control parameters setting.
3 Flow
Flow parameters setting.
4 Speed
Speed parameters setting.
5 Load
Load parameters setting.
6 Save/Print
Weight record parameters setting.
7 Comm. Port
Communication port parameters setting.
8 I/O
Input&output parameters setting.
9 Display
Display and operation interface parameters setting.
10 Date/Time
Date/Time parameters setting.
F2 Calibration
1 Zero Cal.
Zero Calibration without loading for correcting Zero Value.
2 Span Cal. Dyn.
Dynamic Span Calibration with loading measured materials or Poise
Weights for correcting Span Coefficient.
3 Span Cal.Stat1
Static Span Calibration with a measured chain weight as a continuous
and steady load on the running belt weigher for correcting Span
Coefficient.
4 Span Cal.Stat2
Static Span Calibration with a measured Hanging Weight as a steady
load on the running belt weigher for correcting Span Coefficient.
5 Span Cor. Seg.
Segmenting Span Correction. After doing Dynamic or Static Span
Calibration, further corrections for 3 [AD Value: 0~60000] linear
segments are optional for correcting Correction Coefficient 1~3.
6 Speed Cal.
Speed Coefficient Calibration.
Keep the belt weigher running at a constant speed. After the running
time of a revolution being measured with using a stopwatch, do this
operation for correcting Speed Coefficient.
7 Length Cal.
Belt Length Calibration.
Keep the belt weigher running at a constant speed. After the running
time of a revolution being measured with using a stopwatch, do this
operation for correcting Belt Length.