background image

Chapter 5 Notes

www.supmea.com

5

Chapter 5 Notes

Read wiring diagram carefully before installation.

Turn off the power and the valve of the tested
medium during installing and disassembling, the
pressure is reduced to atmosphere pressure to avoid
accidents caused by medium ejection.

Make sure the transmitter is firmly connected and
properly grounded during installing, avoid vibration
and strong EMI environment. Ensure the good
grounding in outdoor installation, and lightning
protection measures should be taken to prevent
lightning from damaging the products.

For the accuracy of measurement, the fluidity of the
medium should be ensured.

It prohibited to insert hard objects into the pressure
hole to prevent damaging the sensor diaphragm.

Prevent the cable damages so that fluid could not
enter transmitter cavity through the damages and
signal wire joint, which will damage the product.

Explosion-proof products should be used in the
working conditions requiring explosion protection.

Avoid serious personal injury and heavy property loss
caused by incorrect operation and selection.

Summary of Contents for SUP-P260-M4

Page 1: ...EN1 Supmea Automation Co Ltd www supmea com info supmea com Headquarters 5th floor Building 4 Singapore Hangzhou Science Technology Park No 6 street Hangzhou Economic Development Area Hangzhou 310018...

Page 2: ...by the false operation After reading please keep it in a place convenient for reading at any time for reference during operation Note Modification of this manual s contents will not be notified due t...

Page 3: ...edictable damage caused directly or indirectly by improper operation of the user Package contents After opening the box please confirm the package contents before starting the operation If you find th...

Page 4: ...ontents Chapter 1 Overview 1 Chapter 2 Specifications 2 Chapter 3 Dimension and Structure 3 Chapter 4 Wiring 4 Chapter 5 Notes 5 Chapter 6 Warranty After sales Service 6 Chapter 7 Communication Protoc...

Page 5: ...el transmitter is applied to fluid depth measurement at industrial areas transfers measured depth value to standard signal such as 4 20 mA 0 5 V RS485 It matches various instruments and is widely used...

Page 6: ...Level 0 100 m Accuracy Temperature 1 5 Level 0 5 Stability 0 25 FS Year Zero temperature drift 0 05 FS Sensitivity temperature drift 0 05 FS Compensation temperature 0 50 Medium temperature 20 65 Sup...

Page 7: ...Chapter 3 Dimension and Structure www supmea com 3 Chapter 3 Dimension and Structure Integrated measurement of liquid level temperature removable protective cap welded structure RS485 output Figure 1...

Page 8: ...Chapter 4 Wiring www supmea com 4 Chapter 4 Wiring 4 1 Electrical connectionN Red Vcc Green Vcc Yellow TX A Blue RX B Black Shield Wire 4 2 Wiring diagram Figure 2 RS485 output...

Page 9: ...outdoor installation and lightning protection measures should be taken to prevent lightning from damaging the products For the accuracy of measurement the fluidity of the medium should be ensured It p...

Page 10: ...e and all non customized products are guaranteed to be returned and replaced within 7 days Disclaimers During the warranty period product faults caused by the following reasons are not in the scope of...

Page 11: ...unication Protocol 7 1 Overview This protocol complies with the MODBUS communication protocol and adopts the RTU mode and RS485 half duplex mode in the MODBUS protocol Currently the device supports th...

Page 12: ...of host operation actual value of slave operation 7 4 Format Serial port settings 8 bit data 1 bit stop Example 9600 N 8 1 Meaning 9600bps No check 8 bit data 1 bit stop serial port baud rate supporte...

Page 13: ...3 0X02 0X00 0X01 0X79 0X84 Write command format 06 Function Code example Address Function code Data starting H Data starting L Data H Data L CRC16 L CRC16 H 0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B B R...

Page 14: ...eanings of the commands and data Function Code Data starting address Data type Data byte Data range Directive significance 0x03 Function code read data 0X03 0X0300 Unsigned int 2 1 247 Address 0X03 0X...

Page 15: ...303 Unsigned int 2 0 None Check bit 1 ODD 2 EVEN 0X03 0X0304 Unsigned int 2 0 7 Pressured decimal point 0X03 0X0305 Unsigned int 2 0 7 Emperature decimal point 0X03 0X0306 Float 4 0 5 1 5 Pressure gai...

Page 16: ...Communication Protocol www supmea com 12 0X03 0X030A Float 4 Temperature base value 0X030B 0X03 0X030CUnsigned int 2 0001 kPa Pressure unit 0002 MPa 0003 mmH2O 0004 mH2O 0005 mmOIL 0006 mOIL 0007 Bar...

Page 17: ...DUnsigned int 2 0080 Temperature unit 0081 0X03 0X0404 Float 4 Pressure output value 0X0405 0X03 0X0408 Float 4 Temperature output value 0X0409 0x06 Function code read data 0X06 0X0300 Unsigned int 2...

Page 18: ...0302 19200 38400 57600 115200 0X06 0X0303 Unsigned int 2 0 None Check bit 1 ODD 2 EVEN 0X06 0X0304 Unsigned int 2 0 7 Pressured decimal point 0X06 0X0305 Unsigned int 2 0 7 Emperature decimal point 0X...

Page 19: ...www supmea com 15 0X06 0X0308 Float 4 Pressure base value 0X0309 0X06 0X030A Float 4 Temperature base value 0X030B 0X06 0X030CUnsigned int 2 0001 kPa Pressure unit 0002 MPa 0003 mmH2O 0004 mH2O 0005 m...

Page 20: ...s reading operation 03H function code If these registers are written 06H 10H function code the abnormal response code 02H will be returned The operation data section only supports writing operations 0...

Page 21: ...Chapter 7 Communication Protocol www supmea com 17 data If the wrong data is written the abnormal response code 04H will be returned and the data in the register will not be changed...

Reviews: