X9SPU-F Motherboard User’s Manual
Console Redirection Settings (for EMS)
This feature allows the user to specify how the host computer will exchange
data with the client computer, which is the remote computer used by the user.
Out-of-Band-Mgmt Port
Use this feature to select the port for out-of-band management. The options are
COM1
, COM2, and SOL.
Terminal Type
This feature allows the user to select the target terminal emulation type for Con-
sole Redirection. Select VT100 to use the ASCII character set. Select VT100+
to add color and function key support. Select ANSI to use the extended ASCII
character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters
into one or more bytes. The options are ANSI, VT100, VT100+, and
VT-UTF8
.
Bits Per Second
This item sets the transmission speed for a serial port used in Console Redirec-
tion. Make sure that the same speed is used in the host computer and the client
computer. A lower transmission speed may be required for long and busy lines.
The options are 9600, 19200, 57600, and
115200
(bits per second).
Flow Control
This feature allows the user to set the flow control for Console Redirection to
prevent data loss caused by buffer overflow. Send a "Stop" signal to stop send
-
ing data when the receiving buffer is full. Send a "Start" signal to start sending
data when the receiving buffer is empty. The options are
None,
Hardware RTS/
CTS, and Software Xon/Xoff.
Hardware Health Configuration
Fan Speed Control Mode
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase for effective
system cooling. Select "Full Speed" to allow the onboard fans to run at full speed
(of 100% Pulse Width Modulation Duty Cycle) for maximum cooling. This setting
is recommended for special system configuration or debugging. Select "Standard"
for the onboard fans to run at 50% of the Initial PWM Cycle in order to balance the
needs between system cooling and power saving. This setting is recommended for
regular systems with normal hardware configurations. The options are Full Speed
(@100% of PWM Cycle), and
Standard
(@50% of PWM Cycle).
Summary of Contents for X9SPU-F
Page 1: ...USER S MANUAL Revision 1 0a X9SPU F ...
Page 26: ...1 14 X9SPU F Motherboard User s Manual Notes ...
Page 68: ...3 8 X9SPU F Motherboard User s Manual Notes ...
Page 96: ...4 28 X9SPU F Motherboard User s Manual Notes ...
Page 98: ...A 2 X9SPU F Motherboard User s Manual Notes ...
Page 102: ...B 4 X9SPU F Motherboard User s Manual Notes ...