SUPERSERVER E200-8B User's Manual
2-4
Socket Key
Installing a SO-DIMM Module
1. Align the receptive point on the bottom of the SO-DIMM module against the key
on the memory socket. Note the notches on the side of the SO-DIMM module
and those on the socket to avoid causing damage.
2. Line up the bottom of the SO-DIMM memory module with the edge of the
horizontal socket.
Receptive Point on the
Module
3. Once they are lined up, push the memory module into the memory socket until
the module is securely seated in the socket.
Removing a SO-DIMM Module
1. Use your thumbs to gently push the side clips on both ends of the socket away
from the SO-DIMM module to release it from the locked position.
2. Once the memory module is loosened from the socket, pull it upwards and
outwards to remove it from the socket.
Memory Module Socket
SO-DIMM Memory
Module
Memory Module Socket
SO-DIMM Memory
Module
Socket Side Clip
Socket Side Clip