Power Supply
Type: 3 x 250W with +3.3V, +5V, +12V, -5V and -12V main DC
outputs and a 5V standby output
Input Voltage: 100-240VAC (w/
±
10% tolerance - units are auto-
switching capable)
Input Frequency: 50/60 hz
Maximum Output: +5V and +3.3V: 200W total
+5V, +3.3V and -12V: 400W max.
System Cooling
Two (2) 9-cm chassis cooling fans (hot-swappable)
One (1) 12-cm exhaust fan (not hot-swappable)
Operating Environment
Operating Temperature Range: 0 to 35 degrees C
Humidity Range: 5-90%, non-condensing
Motherboard
Model: P4DP8-G2
Form Factor: Extended ATX
Dimensions: 12 x 13.05 in (304.8 x 331.5 mm)
SC742S-420 chassis:
Chassis
Model: SC742S-420
Form Factor: 4U rackmount/tower
Dimensions: (WxHxD as 4U) 6.94" x 17.125 x 24.125 in. (17.6 x 435 x
612.8 mm)
Operating Systems Supported
Windows NT, Windows 2000, Solaris, Netware, SCO UNIX and Linux
Weight
Net (Bare Bone): ~40 lbs. (~18 kg.)
Gross (Bare Bone): ~54 lbs. (~24.5 kg.)
Regulations:
FCC Class B, CE, UL/CUL, TUV