SUPERSERVER 6028TP-HC1R/HC1TR/HC1FR USER'S MANUAL
2-5 Installing the System into a Rack
This section provides information on installing the chassis into a rack
unit with the quick-release rails provided. There are a variety of rack units on the
market, which may mean the assembly procedure will differ slightly. You should
also refer to the installation instructions that came with the rack unit you are using.
NOTE:
This rail will fit a rack between 26" and 33.5" deep.
Separating the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fixed chassis rail that secures directly
to the server chassis and an outer fixed rack rail that secures directly to the rack
itself (Figure 2-1).
Figure 2-1. Separating the Rack Rails
Separating the Inner and Outer
Rails
1. Locate the rail assembly in the
chassis packaging.
2. Extend the rail assembly by
pulling it outward.
3. Press the quick-release tab.
4. Separate the inner rail
extension from the outer rail
assembly.
1
1
1
2
1
4
1
3
Rail Assembly
Extending the Rails
Quick-Release Tab
Separating
the Inner Rail
Extension
Warning:
do not pick up the server with the front handles. They are
designed to pull the system from a rack only.
Summary of Contents for SUPERSERVER 6028TP-HC1FR
Page 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 6028TP HC1R 6028TP HC1TR 6028TP HC1FR...
Page 5: ...v SUPERSERVER 6028TP HC1R HC1TR HC1FR USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 6028TP HC1R HC1TR HC1FR USER S MANUAL...
Page 18: ...1 8 SUPERSERVER 6028TP HC1R HC1TR HC1FR USER S MANUAL Notes...
Page 26: ...2 8 SUPERSERVER 6028TP HC1R HC1TR HC1FR USER S MANUAL Notes...
Page 30: ...SUPERSERVER 6028TP HC1R HC1TR HC1FR USER S MANUAL 3 4 Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 136: ...A 2 SUPERSERVER 6028TP HC1R HC1TR HC1FR USER S MANUAL Notes...