Chapter 5: Advanced Motherboard Setup
5-3
Gently push
down to pop
the load plate
open.
3. With the lever labeled 'Close 1st'
fully retracted, gently push down
on the 'Open 1st' lever to open the
load plate. Lift the load plate to
open it completely.
4. Using your thumb and the index
fi nger, remove the 'WARNING'
plastic cap from the socket.
5. Use your thumb and index fi nger
to hold the CPU by its edges. Align
the CPU keys, which are semi-
circle cutouts, against the socket
keys.
6. Once they are aligned, carefully
lower the CPU straight down into
the socket. (Do not drop the CPU
on the socket. Do not move the
CPU horizontally or vertically and
do not rub the CPU against any
pins of the socket, which may
damage the CPU or the socket.)
WARNING!
WAR
NIN
G!
OPEN 1st
OPEN
1st
WARNING!
WAR
NIN
G!
Socket Keys
CPU Keys