Fan Speed Control Mode
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase for effective
system cooling. Select "Full Speed" to allow the onboard fans to run at full speed
(of 100% Pulse Width Modulation Duty Cycle) for maximum cooling. This setting
is recommended for special system con
fi
guration or debugging. Select "Standard"
for the onboard fans to run at 50% of the Initial PWM Cycle in order to balance the
needs between system cooling and power saving. This setting is recommended
for regular systems with normal hardware con
fi
gurations. Select "Optimal" for the
onboard fans to run at 30% of the Initial PWM Cycle for best power ef
fi
ciency and
maximum quietness. The options are Full Speed (@100% of PWM Cycle),
Standard
(@50% of PWM Cycle), and Optimal (@30% of PWM Cycle).
CPU Temperature Display Mode
This feature displays the CPU temperature detected by DTS (i.e., +34
o
C) or tem-
perature status in text ("Low", "Medium" or "High"). The options are
Text Mode
or DTS.
If Text Mode is selected, the CPU Temperature Display Mode will show the CPU
temperature status as follows:
Low – This level is considered as the ‘normal’ operating state. The CPU
temperature is well below the CPU ‘Temperature Tolerance’. The mother-
board fans and CPU will run normally as con
fi
gured in the BIOS (Fan Speed
Control).
User intervention: No action required.
Medium – The processor is running warmer. This is a ‘precautionary’ level
and generally means that there may be factors contributing to this condition,
but the CPU is still within its normal operating state and below the CPU
‘Temperature Tolerance’. The motherboard fans and CPU will run normally
as con
fi
gured in the BIOS. The fans may adjust to a faster speed depending
on the Fan Speed Control settings.
User intervention: No action is required. However, consider checking the CPU
fans and the chassis ventilation for blockage.
Summary of Contents for SUPERSERVER 5017C-MF
Page 1: ...SUPERSERVER 5017C MF SUPER USER S MANUAL 1 0a ...
Page 5: ...v Preface Notes ...
Page 14: ...1 6 SUPERSERVER 5017C MF User s Manual Notes ...
Page 22: ...2 8 SUPERSERVER 5017C MF User s Manual Figure 2 4 Installing the Server into a Telco Rack ...
Page 26: ...2 12 SUPERSERVER 5017C MF User s Manual Notes ...
Page 30: ...3 4 SUPERSERVER 5017C MF User s Manual Notes ...
Page 60: ...5 26 SUPERSERVER 5017C MF User s Manual Notes ...
Page 66: ...6 6 SUPERSERVER 5017C MF User s Manual Figure 6 3 Removing the DVD ROM Drive ...
Page 90: ...4 22 SUPERSERVER 5017C MF User s Manual Notes ...
Page 92: ...A 2 SUPERSERVER 5017C MF User s Manual Notes ...