ERVER 5017C-MF User's Manual
5-3 Connecting
Cables
Now that the processors are installed, the next step is to connect the cables to the
motherboard. These include the data (ribbon) cables for the peripherals and control
panel and the power cables.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully
routed in precon
fi
gured systems to prevent them from blocking the
fl
ow of cooling
air that moves through the system from front to back. If you need to disconnect any
of these cables, you should take care to reroute them as they were originally after
reconnecting them (make sure the red wires connect to the pin 1 locations). If you
are con
fi
guring the system, keep the air
fl
ow in mind when routing the cables.
The following data cables (with their motherboard connector locations noted)
should be connected.
See the motherboard layout diagram in this chapter for connector locations.
•
Control Panel cable (JF1, see next page)
•
SATA cables (SATA1 ~ SATA5)
•
SGPIO cable (T-SGPIO1 to SATA backplane)
Connecting Power Cables
The X9SCL-F has a 24-pin primary power supply connector designated "JPW1"
for connection to the ATX power supply. Connect the appropriate connector from
the power supply to JPW1 to supply power to the motherboard. See the Connector
De
fi
nitions section in this chapter for power connector pin de
fi
nitions.
In addition, your power supply must be connected to the 8-pin Processor Power
connector at JPW2.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure
5-1 for the pin locations of the various front control panel buttons and LED indica-
tors. Please note that even and odd numbered pins are on opposite sides of each
header.
Summary of Contents for SUPERSERVER 5017C-MF
Page 1: ...SUPERSERVER 5017C MF SUPER USER S MANUAL 1 0a ...
Page 5: ...v Preface Notes ...
Page 14: ...1 6 SUPERSERVER 5017C MF User s Manual Notes ...
Page 22: ...2 8 SUPERSERVER 5017C MF User s Manual Figure 2 4 Installing the Server into a Telco Rack ...
Page 26: ...2 12 SUPERSERVER 5017C MF User s Manual Notes ...
Page 30: ...3 4 SUPERSERVER 5017C MF User s Manual Notes ...
Page 60: ...5 26 SUPERSERVER 5017C MF User s Manual Notes ...
Page 66: ...6 6 SUPERSERVER 5017C MF User s Manual Figure 6 3 Removing the DVD ROM Drive ...
Page 90: ...4 22 SUPERSERVER 5017C MF User s Manual Notes ...
Page 92: ...A 2 SUPERSERVER 5017C MF User s Manual Notes ...