1-1 Overview
Some Supermicro switches can be equipped with an optional rail kit (CSE-PT52L)
to make it easy to install them in a rack. This manual provides instructions for in-
stalling the CSE-PT52L mounting rails onto a rack and for installing the switch into
the mounting rails. Following these steps in the order given should enable you to
have the system operational within a minimum amount of time.
1-2 Unpacking the System
You should inspect the box the switch was shipped in and note if it was damaged
in any way. If the switch itself shows damage you should file a damage claim with
the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold your switch. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fields are generated. You will also need
it placed near a grounded power outlet. Be sure to read the Rack, General and
Lithium Battery Precautions in the next section.
1-3 Preparing for Setup
The optional rail kit (CSE-PT52L) ships in a separate box and that box should
include two sets of rail assemblies, two rail mounting brackets and the mounting
screws needed to install the system into the rack. Read this section in its entirety
before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front
•
door completely (~25 inches).
Leave approximately 30 inches of clearance in the back of the rack to allow for
•
sufficient airflow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated
•
equipment rooms, service closets and similar environments).