4-32
A1SAi & A1SRi Series Motherboard User’s Manual
Smbios Event Long Standard Settings
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The
options are
Disabled
and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurenc-
es that a duplicate event must happen before the MECI counter is incremented.
This is a numeric value. The default value is
1
.
METW
The Multiple Event Time Window (METW) defines number of minutes must pass
between duplicate log events before MECI is incremented. This is in minutes, from
0 to 99. The default value is
60
.
Custom Options
Log OEM Codes
Select Enabled to log the status of OEM EFI codes. The options are
Enabled
and
Disabled.
Convert OEM Codes
Select Enabled to convert the OEM Status codes to the standard SMBIOS codes.
The options are Enabled and
Disabled
.
View SMBIOS Event Log
This section displays the contents of the SMBIOS Event Log.