Chapter 6: Advanced Chassis Setup
6-9
6-6 Power
Supply
The SuperServer 2015TA-HTRF server has two 720 watt power supply modules to
provide redundant power for the system. If either of the two power supply modules
fail, the other module will take the full load and allow the system to continue opera-
tion without interruption. The LED on the control panel will
fl
ash slowly (about 4
seconds on and 4 off) and remain
fl
ashing until the failed unit has been replaced.
Replacement units can be ordered directly from Supermicro (see contact information
in the Preface). The power supply units have a hot-swap capability, meaning you
can replace the failed unit without powering down the system.
Removing/Replacing the Power Supply (Figure 6-7)
Disconnect the AC power cord from the failed module.
1.
Push the colored release tab to the side and pull the power module out with
2.
the handle provided.
Replace the failed power supply module with the exact same model from
3.
Supermicro.
Carefully insert the new module into position in the chassis and push it in until
4.
fully seated. You should see the LED on the rear of the module turn amber
showing that power (from the backup module) is present.
Reconnect the AC power cord to the new module.
5.
Summary of Contents for 2U Twin3 2015TA-HTRF
Page 1: ...SUPER USER S MANUAL Revision 1 0 2U Twin3TM SuperServer 2015TA HTRF ...
Page 5: ...v Preface Notes ...
Page 25: ...Chapter 2 Server Installation 2 11 Figure 2 6 Removing a Node from the System ...
Page 26: ...2 12 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Page 30: ...3 4 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Page 54: ...5 20 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Page 64: ...6 10 SUPERSERVER 2015TA HTRF User s Manual Figure 6 7 Removing the Power Supply Release Tab ...
Page 88: ...7 24 SUPERSERVER 2015TA HTRF User s Manual Notes ...
Page 90: ...A 2 SUPERSERVER 2015TA HTRF User s Manual Notes ...