2-8
S
UPER
S
ERVER 1027R-72BRFTP User's Manual
Installing the Server into a Telco Rack
To install the chassis into a Telco type rack, use two L-shaped brackets on either
side of the chassis (four total). First, determine how far the server will extend out the
front of the rack. Larger chassis should be positioned to balance the weight between
front and back. If a bezel is included on your server, remove it. Then attach the two
front brackets to each side of the chassis, then the two rear brackets positioned with
just enough space to accommodate the width of the telco rack. Finish by sliding the
chassis into the rack and tightening the brackets to the rack.
Figure 2-5: Installing the Server into a Telco Rack
Stability hazard
. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Warning
: do not pick up the server with the front handles. They are designed
to pull the system from a rack only.
Summary of Contents for 1027R-72BRFTP
Page 1: ...SUPERSERVER 1027R 72BRFTP SUPER USER S MANUAL 1 0b ...
Page 5: ...v Preface Notes ...
Page 14: ...1 6 SUPERSERVER 1027R 72BRFTP User s Manual Notes ...
Page 26: ...3 4 SUPERSERVER 1027R 72BRFTP User s Manual Notes ...
Page 46: ...4 20 SUPERSERVER 1027R 72BRFTP User s Manual Notes ...
Page 78: ...5 32 SUPERSERVER 1027R 72BRFTP User s Manual Notes ...
Page 90: ...6 12 SUPERSERVER 1027R 72BRFTP User s Manual Notes ...
Page 126: ...A 2 SUPERSERVER 1027R 72BRFTP User s Manual Notes ...