Chapter 4: BIOS
4-17
Hardware Monitor Logic
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The options are 70
o
C, 75
o
C,
80
o
C
and 85
o
C.
Highlight this and hit <Enter> to see monitor data for the following items:
CPU1 Temperature
: This item displays CPU1 Temperature.
CPU2 Temperature
: This item displays CPU2 Temperature.
System Temperature
: This item displays the System Temperature.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When
the CPU on-die temperature increases, the fan speed will also increase, and vice
versa. The Options are:
1. Full Speed at 12V
. 2. Optimized for Server with
3-pin Fans.
Fan 1-Fan5
: If the feature of Auto Fan Control is enabled, the BIOS will
automatically display the status of the fans indicated in this item.
Vcore A/Vcore B
: These items display the Voltage status of CPU 1 and CPU 2.
P3V3
: This item displays the +3.3V voltage status.
P5V
: This item displays the +5V voltage status.
N12V
: This item displays the -12V voltage status.
P12V
: This item displays the +12V voltage status.
VDD
: This item displays the VDD status.
P5Vsb
: This item displays the voltage status of +5V Standby power.