D-2
S
UPER
S
ERVER 6014L-T User's Manual
Weight
Net (Bare Bone): 28 lbs. (12.7 kg.)
Net (Gross): 34 lbs. (15.5 kg.)
System Cooling
Two (2) 4-cm fans
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 115V to 230V (5A max)
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 260W (Model# EFA250, Part# PWS-0055)
Rated Output Voltages: +3.3V (20A), +5V (25A), +12V (13A), -12V (.8A),
+5Vsb (2A)
BTU Rating
1372 BTUs/hr (for rated output power of 260W)
Operating
Environment
Operating Temperature: 10º to 35º C (50º to 90º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic
Emissions:
FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B
Electromagnetic
Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN
60950/IEC
60950-Compliant
UL
Listed
(USA)
CUL
Listed
(Canada)
TUV
Certifi
ed
(Germany)
CE Marking (Europe)
Summary of Contents for SUPERSERVER 6014L-T
Page 1: ...SUPER SUPERSERVER 6014L T USER S MANUAL Revision 1 0...
Page 5: ...v Preface Notes...
Page 10: ...x Notes SUPERSERVER 6014L T User s Manual...
Page 18: ...1 8 SUPERSERVER 6014L T User s Manual Notes...
Page 27: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 32: ...3 4 SUPERSERVER 6014L T User s Manual Notes...
Page 68: ...6 8 SUPERSERVER 6014L T User s Manual Notes...
Page 98: ...B 8 SUPERSERVER 6014L T User s Manual Notes...
Page 104: ...C 6 SUPERSERVER 6014L T User s Manual...
Page 118: ...C 20 SUPERSERVER 6014L T User s Manual Notes...