Supermicro SUPERSERVER 6013P-i User Manual Download Page 34

S

UPER

S

ERVER 6013P-i Manual

4-4

4-4

Operating Precautions

Care must be taken to assure that the chassis cover is in place when

the 6013P-i is operating to assure proper cooling.  Out of warranty

damage to the 6013P-i system can occur if this practice is not strictly

followed.

!

Summary of Contents for SUPERSERVER 6013P-i

Page 1: ...SUPERSERVER 6013P i USER SMANUAL 1 0a SUPER NIC 1 NIC 2 RESET...

Page 2: ...R INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED W...

Page 3: ...apter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the SUPER X5DPR iG2 serverboard and the SC812L cha...

Page 4: ...this chapter when adding or removing processors or main memory and when reconfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the 1U SC812L rac...

Page 5: ...v Preface Notes...

Page 6: ...2 1 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 2 4 Installing the SuperServer 6013P i into a Rack 2 3 Identifying the Sections of the Rack Rails 2 3 Installing the Chass...

Page 7: ...the Control Panel 5 6 5 4 I O Ports 5 7 5 5 Installing Memory 5 7 5 6 Adding PCI Cards 5 9 5 7 Serverboard Details 5 10 X5DPR iG2 Layout 5 10 X5DPR iG2 Quick Reference 5 11 5 8 Connector Definitions 5...

Page 8: ...1 GLAN2 LEDs 5 21 5 11 Hard Drive Connections 5 22 IDE Connectors 5 22 5 12 Installing Software Drivers 5 23 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 6 2 Control Panel 6 2 6 3...

Page 9: ...Table of Contents ix 7 6 Power 7 15 7 7 Boot 7 17 7 8 PIR 7 19 7 9 Exit 7 21 Appendices Appendix A BIOS POST Messages A 1 Appendix B BIOS POST Codes B 1 Appendix C System Specifications C 1...

Page 10: ...SUPERSERVER 6013P i User s Manual x Notes...

Page 11: ...ion to the mainboard and chassis various hardware components may have been included with your SuperServer 6013P i as listed below Up to two 2 604 pin Intel Xeon processors of up to 3 06 GHz optional T...

Page 12: ...for a DDR 266 PC2100 memory interface which provides a total bandwidth of up to 4 2 GB s The ICH3 interface is a 266 MB sec point to point connection using an 8 bit wide 66 MHz base clock at a 4x data...

Page 13: ...Graphics Controller The X5DPR iG2 features an integrated ATI video controller based on the Rage XL graphics chip Rage XL fully supports sideband addressing and AGP texturing This onboard graphics pack...

Page 14: ...a SuperServer 6013P i the SC812L chassis includes a 350W cold swap power supply Control Panel The SC812L control panel provides important system monitoring and control information LEDs indicate power...

Page 15: ...gurations The SC812L in cludes two heavy duty 10 cm blower fans located in the middle of the chassis These fans operate continuously at full rpm If they break down the ambient air temperature inside t...

Page 16: ...ess SuperMicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Tech...

Page 17: ...e if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the Sup...

Page 18: ...ble before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable Server Precautions Review the e...

Page 19: ...should have received two rack rail assemblies with the SuperServer 6013P i Each of these assemblies consist of three sections an inner fixed chassis rail that secures to the 6013P i A and an outer fix...

Page 20: ...functions The first is to lock the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended f...

Page 21: ...the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server...

Page 22: ...ou are installing the SuperServer 6013P i into a Telco type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will be the p...

Page 23: ...cover from the chassis to gain full access to the inside of the server 2 Check the CPUs processors You should have one or two processors already installed into the system board Each processor needs i...

Page 24: ...e sure all power and data cables are properly connected and not blocking the chassis airflow See Chapter 5 for details on cable connec tions Also check the air seals for damage The air seals are locat...

Page 25: ...was carefully designed to direct sufficient cooling air flow to the components that generate the most heat Note that all power and data cables have been routed in such a way that they do not block th...

Page 26: ...2 10 SUPERSERVER 6013P i Manual Notes...

Page 27: ...switch on the power supply 3 2 Control Panel Buttons There are two push button buttons located on the front of the chassis These are in order from left to right a reset button and a power on off butto...

Page 28: ...ure being too warm You should also check to make sure that the chassis cover is installed and that all fans are present and operat ing normally Verify that the heatsinks are installed properly see Cha...

Page 29: ...erboard LEDs There are several LEDs on the motherboard The power LED is located near the JF2 connector and indicates that system power is present on the motherboard when illuminated There are also fou...

Page 30: ...SUPERSERVER 6013P i User s Manual 3 4 Notes...

Page 31: ...emory modules and the CD ROM and floppy drives When disconnecting power you should first power down the system with the operating system and then unplug the power cords of all the power supply units i...

Page 32: ...nto a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boa...

Page 33: ...use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Page 34: ...perating Precautions Care must be taken to assure that the chassis cover is in place when the 6013P i is operating to assure proper cooling Out of warranty damage to the 6013P i system can occur if th...

Page 35: ...hat the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to...

Page 36: ...the fan Also do not place the serverboard on a conductive surface which can damage the BIOS battery and prevent the system from booting up 1 Lift the lever on the CPU socket Lift the lever completely...

Page 37: ...into their proper position When correctly installed the retention clips should click into place and the three black tabs on the CPU retention pieces should protrude fully through the corresponding ho...

Page 38: ...5 4 SUPERSERVER 6013P i User s Manual Figure 5 2 Heatsink Installation...

Page 39: ...ng them make sure the red wires connect to the pin 1 locations If you are configuring the sys tem keep the airflow in mind when routing the cables The following data cables with their severboard conne...

Page 40: ...Figure 5 3 for the pin locations of the various front control panel buttons and LED indicators Please note that even and odd numbered pins are on opposite sides of each header All JF2 wires have been...

Page 41: ...nterleaved to improve performance see step 1 DIMM Installation See Figure 5 5 1 Insert the desired number of DIMMs into the memory slots starting with Bank 1 DIMM 1A DIMM 1B The memory scheme is inter...

Page 42: ...e your thumbs to gently push each release tab outward to free the DIMM from the slot Memory Support The X5DPR 8G2 only supports ECC registered DDR 266 200 PC2100 1600 memory If you are using 533 MHz F...

Page 43: ...above Begin by swing ing the release tab on the I O backpanel shield out to the left for the PCI slot Insert the PCI card into the correct slot on the butterfly riser card depending on whether it is...

Page 44: ...8 Keyboard J29 USB0 1 COM1 GLAN2 VGA GLAN1 MCH Rage XL ICH3 CHS FAN3 P64H2 BATTERY COM2 BIOS Speaker Zero Channel RAID Socket IPMI IDE 1 IDE 2 FLOPPY SMB WOL FPUSB0 1 SLP JBT1 WD IR CIR USB2 PWRLED Sp...

Page 45: ...R Primary ATX Power Connector COM1 COM2 COM1 COM2 Serial Port Connector CPU1 CPU2 CPU 1 and CPU2 Sockets CPU CHS FAN CPU 1 2 Chassis Fan Headers DIMM 1A DIMM 3B Memory RAM Slots GLAN1 2 Ethernet Ports...

Page 46: ...upply 20 pin Connector Pin Number Definition 11 3 3V 12 12V 13 COM 14 PS_ON 15 COM 16 COM 17 COM 18 5V 19 5V 20 5V Pin Number Definition 1 3 3V 2 3 3V 3 COM 4 5V 5 COM 6 5V 7 COM 8 PW OK 9 5VSB 10 12V...

Page 47: ...C1 LED The NIC1 Network Interface Con troller LED connection is located on pins 11 and 12 of JF2 Attach the NIC1 LED cable to display net work activity Refer to the table on the right for pin definiti...

Page 48: ...USB0 1 Two Universal Serial Bus ports are located beside the PS 2 key board mouse ports USB0 is the bottom connector and USB1 is the top connector See the table on the right for pin definitions Univer...

Page 49: ...e on the right for pin definitions The mouse port is green and the keyboard port is purple See Figure 2 3 PS 2 Keyboard and Mouse Port Pin Definitions J29 Pin Num ber 1 2 3 4 5 6 Definition Data NC Gr...

Page 50: ...Speaker NMI On the JDI header pins 1 3 are for a power LED pins 4 7 are for the speaker and pins 8 9 are for the NMI connection See the table on the right for speaker pin defini tions Note The speake...

Page 51: ...LAN connector and cable Wake On Ring The Wake On Ring header is des ignated JWOR This function al lows your computer to receive and wake up by an incoming call to the modem when in sustpend state See...

Page 52: ...CMOS CMOS Clear Jumper Settings JBT1 Jumper Position 1 2 2 3 Definition Normal CMOS Clear Position 1 2 Position 2 3 Normal CMOS Clear 5 9 Jumper Settings Explanation of Jumpers To modify the operatio...

Page 53: ...2 to enable VGA See the table on the right for jumper settings Jumper Position 1 2 2 3 Definition Enabled Disabled VGA Enable Disable Jumper Settings JP4 3rd Power Supply Alarm Enable Disable The sys...

Page 54: ...Off Off JP11 Off On On JP12 Off Off Pins 1 2 Gb LAN Bus Speed Settings JP10 JP11 JP12 Speaker Enable Disable On the JD1 header add a jumper to pins 6 7 to enable the onboard speaker If you wish to us...

Page 55: ...de the VGA port have two LEDs On the Gb LAN port the yellow left LED indicates activity while the right LED may be green orange or off to indicate the speed of the connection See the table at right fo...

Page 56: ...21 DRQ3 23 I O W rite 25 I O Read 27 IOCHRDY 29 DACK3 31 IRQ14 33 Addr 1 35 Addr 0 37 Chip Select 0 39 Activity Pin Number Function 2 GND 4 Host Data 8 6 Host Data 9 8 Host Data 10 10 Host Data 11 12...

Page 57: ...erting this CD into your CD ROM drive the display shown in Figure 5 8 should appear If this display does not appear double click on the My Computer icon and then on the icon representing your CD ROM d...

Page 58: ...5 24 SUPERSERVER 6013P i User s Manual Notes...

Page 59: ...damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grou...

Page 60: ...o the appro priate header on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The control panel LE...

Page 61: ...eplacing System Cooling Fans 1 Removing a fan Power down the server and remove the power cord as a safety precaution Remove the chassis cover and detach the fan wires from their connection to the moth...

Page 62: ...ssing the Drive Bays To install remove a disk drive in one of the IDE drive bays you will need to gain access to the inside of the 6013P i by removing the top cover of the chassis see Figure 6 3 Figur...

Page 63: ...hard disk drive to add a hard disk drive install it into one of the removed empty drive carriers with the printed circuit board side toward the carrier down so that the drive s mounting holes align w...

Page 64: ...ontrol panel and the switch on the power supply off then unplug the power cord from the system and all peripheral devices Remove the chassis cover by pressing the two release buttons on the top of the...

Page 65: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Removing Replacing the Power Supply...

Page 66: ...6 8 SUPERSERVER 6013P i Manual Notes...

Page 67: ...ttle electrical power When the computer is turned off a back up battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the computer is powered on the computer...

Page 68: ...sing Delete immediately after turning the system on or 2 When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to activate th...

Page 69: ...he correct data Press the Enter key to save the data Phoenix BIOS Setup Utility Main Advanced Security Power Boot Exit System Time 16 19 20 System Date 02 02 02 Legacy Diskette A 1 44 1 25 MB Legacy D...

Page 70: ...r Slave and IDE Secondary Master Slave slots Hit Enter to activate the following sub menu screen for detailed options of these items Set the correct configurations accordingly The items included in th...

Page 71: ...rol This item determines whether Phoenix BIOS will access the IDE Primary Master Device via LBA mode The options are Enabled and Disabled 32 bit I O Selects 32 bit I O operation Options are Enabled an...

Page 72: ...em Options are Other Win95 Win98 WinMe and Win2000 Quick Boot Mode If enabled this feature will speed up the POST Power On Self Test routine after the computer is turned on The settings are Enabled an...

Page 73: ...em Specific Help window for details I O Device Configuration Access the submenu to make changes to the following settings Power Loss Control This setting allows you to choose how the system will react...

Page 74: ...Normal and IR for an infrared device Base I O Address Select the base I O address for serial port B The options are 3F8 2F8 3E8 and 2E8 Interrupt Select the IRQ interrupt request for serial port B Opt...

Page 75: ...parallel port The options are Primary and Secondary Large Disk Access Mode This setting determines how large hard drives are to be accessed The options are DOS or Other for Unix Novellle NetWare and o...

Page 76: ...ons required to qualify as an ECC error Options are None Single Bit Multiple Bit and Both Advanced Processor Options Access the submenu to make changes to the following settings CPU Speed This is a di...

Page 77: ...make changes to the following settings Event Log Validity This is a display not a setting informing you of the event log validity Event Log Capacity This is a display not a setting informing you of th...

Page 78: ...e redirection Console Type Choose from the available options to select the console type for console redirection Flow Control Choose from the available options to select the flow control for console re...

Page 79: ...een used and Set means a supervisor password has been entered for the system User Password Is This displays whether a user password has been entered for the system Clear means such a password has not...

Page 80: ...r key When prompted type the user s password in the dialogue box to set or to change the user s password which allows access to the system at boot up Password on Boot This setting allows you to requir...

Page 81: ...r Interface power management on your system Power Savings This setting sets the degree of power saving for the system The options are Disabled Customized Maximum Power Savings and Maximum Performance...

Page 82: ...p at the time specified in the next setting Resume Time Use this setting to specify the time you want the system to wake up the above setting must be set to On Enter the time with the number keys Resu...

Page 83: ...able Devices Highlight and press Enter to expand the field See details on how to change the order and specs of removable devices in the Item Specific Help window CD ROM Drive See details on how to cha...

Page 84: ...nge the order and specs of hard drives in the Item Specific Help window Network Boot See details on how to change the order and specs of network boot devices in the Item Specific Help window Intel UND...

Page 85: ...keys and pressing Enter All PIR BIOS Setup options are described in this section Select the Processor s PIR Selects the processor PIR Options are A0h A1h A2h A3h A4h A5h A6h A7h A8h A8h AAh ABh ACh AD...

Page 86: ...ta Feature Data Other Data OEM Data Hardware Monitor Logic Highlight this and hit Enter to see monitor data for the following items CPU1 Temperature CPU2 Temperature System Temperature CPU Fan1 CPU1 C...

Page 87: ...ys You should see the following display All Exit BIOS settings are described in this section Phoenix BIOS Setup Utility Main Advanced Security Power Boot PIR Exit Exit Saving Changes Exit Discarding C...

Page 88: ...y without saving any changes you may have made Load Setup Defaults Highlight this item and hit Enter to load the default settings for all items in the BIOS Setup These are the safest settings to use D...

Page 89: ...ed Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not...

Page 90: ...POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On systems...

Page 91: ...tware NMI Failed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBIOS2 test error Fail Safe Timer takes too long device Address Conflict Add...

Page 92: ...ly tested nnnn kB System RAM Passed Where nnnn is the amount of system RAM in kilobytes successfully tested One or more I2O Block Storage Devices were excluded from the Setup Boot Menu There was not e...

Page 93: ...Write down and follow the information shown on the screen Press F2 to enter Setup Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identified Run the I2O Configu...

Page 94: ...A 6 SUPERSERVER 6013P i Manual Notes...

Page 95: ...initialize video and write the error in the top left corner of the screen The following is a list of codes that may be written to port 80h Appendix B BIOS POST Codes POSTCode Description 02h Verify R...

Page 96: ...tart shut down 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot...

Page 97: ...80h Disable onboard Super I O ports and IRQs 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Configure non MCD IDE controllers 84h Detect and install external paral...

Page 98: ...uietBoot optional B6h Check password optional B7h Initialize ACPI BIOS B9h Prepare Boot BAh Initialize SMBIOS BBh Initialize PnP Option ROMs BCh Clear parity checkers BDh Display MultiBoot menu BEh Cl...

Page 99: ...ze EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F5h Cle...

Page 100: ...B 6 SUPERSERVER 6013P i Manual Notes...

Page 101: ...DDR DIMM sockets supporting up to 12 GB of registered ECC DDR 200 PC1600 SDRAM Note Interleaved memory requires memory to be installed two at a time Memory speed dependant on processor s front side bu...

Page 102: ...ctor X5DPR iG2 motherboard Extended ATX 12 x 13 in 304 8 x 330 2 mm SC812L chassis 1U rackmount Operating Systems Supported Windows NT Windows 2000 Solaris Netware SCO UNIX and Linux Dimensions 16 7 x...

Reviews: