Chapter 3: Maintenance and Component Installation
(DDR4 Only) 2SPC Memory Configuration with x8 DIMMs
Total # of
DIMMs
DDR Channel
Number
of
Ranks
Virtual
Lock
Step
DIMM Population
within an IMC
(Note: Uniformly
populate with x8
DRAMs DIMMs)
1 x8 DIMM
Must be installed on iMC0 DDR Channel 0
1
N/A
>1
SVLS
2 x8
DIMMs
DDR0: Populate with 1 DIMM
DDR1: Populate identically as DDR0
1
N/A
>1
SVLS
3 x8
DIMMs
DDR0: Populate with 1 DIMM
DDR1: Populate identically as DDR0
DDR2: Populate identically as DDR1
1
N/A
>1
SVLS
4 x8
DIMMs
DDR0: Populate with 2 DIMMs
DDR1: Populate identically as DDR0
x
SVLS
5 x8
DIMMs
DDR Channel 0, 1, 2: DIMM0 is populated with identical DIMMs,
DDR Channel 0, 1: DIMM1 is populated with identical DIMMs
>1
SVLS
6 x8
DIMMs
Populate 2 DIMMs per DDR channel
x
SVLS
DIMM Population
within an IMC
(Note: Non-equal
in rank pair of x8
DIMMs)
1 pair of
DIMMs
DDR0: Populate with 1 DIMM
DDR1: Populate the second DIMM (for best performance)
1
N/A
>1
SVLS
2 pairs of
DIMMs
DDR0: Populate with 1 pair of non-equal rank DIMMs
DDR1: Populate identically as DDR0
1
N/A
>1
SVLS
3 pairs of
DIMMs
DDR0: Populate with 1 pair of non-equal rank DIMMs
DDR1: Populate identically as DDR0
DDR2: Populate identically as DDR1
x
SVLS
2 pairs+1
(5DIMMs)
DDR0: Populate with 1 pair of non-equal rank DIMMs
DDR1: Populate with identical DIMMs as DDR0
DDR2: DIMM0 is populated with identical DIMM as DDR1
>1
SVLS
Summary of Contents for SuperServer 2049U-TR4
Page 1: ...USER S MANUAL Revision 1 0 SuperServer 2049U TR4...
Page 46: ...SuperServer 2049U TR4 User s Manual 46 1 2 Figure 3 9 Removing a Drive Carrier...
Page 112: ...112 SuperServer 2049U TR4 User s Manual...
Page 141: ...Appendix E Traditional Chinese Version of Safety Warnings 141 1 2 3 4 5 1 2 3 4 1 2 3 4 1 2...