Chapter 2: Server Installation
23
Note:
Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.
Figure 2-6. Installing into a Rack
Ball-Bearing Shuttle
Sliding the Chassis onto the Rack Rails
Warning:
Mounting the system into the rack requires at least two people to support the
chassis during installation. Please follow safety recommendations printed on the rails.
Installing the Chassis into a Rack
1. Extend the outer rails as illustrated above.
2. Align the inner rails of the chassis with the outer rails on the rack.
3. Slide the inner rails into the outer rails, keeping the pressure even on both sides. When
the chassis has been pushed completely into the rack, it should click into the locked
position.
4. Optional screws may be used to hold the front of the chassis to the rack.
Caution:
Do not pick up the server with the front handles. They are designed to pull
the system from a rack only.