6-4
SUPERSERVER 2028TR-HTR/HTFR/H72R/H72FR User's Manual
Figure 6-4. Installing an Air Shroud
Note
: The figure is an example shroud and serverboard. Yours may differ slightly.
6-4 Air Shrouds
Air shrouds concentrate airflow to maximize fan efficiency. The SC217 chassis
requires air shrouds for each serverboard node. Air shrouds vary depending upon
the serverboard used. See the illustrations below.
Installing an Air Shroud
1. Cut a notch into the corner of the air shroud as shown below to allow more
airflow to cool the LSI 2208 chip.
2. Make sure that the serverboard expansion cards (if applicable) and all
components are properly installed in each serverboard node.
3.
Place the first air shroud over the serverboard, as shown below. The air
shroud sits behind the system fans and goes over the top of the serverboard
and its components.
4. Repeat the procedure for the remaining node.
Air Shroud
Cut Notch