Chapter 3: System Interface
3-3
3-4 Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive
carrier displays two status LEDs on the front of the carrier.
Drive Carrier LEDs
LED Color
Blinking Pattern
Behavior for Device
Activity LED
Blue
Solid On
SAS/NVMe drive installed
Blue
Blinking
I/O activity
Status LED
Red
Solid On
Failed drive for SAS/SATA/NVMe with
RSTe support
Red
Blinking at 1 Hz
Rebuild drive for SAS/SATA/NVMe with
RSTe support
Red
Blinking with two blinks
and one stop at 1 Hz
Hot spare for SAS/SATA/NVMe with
RSTe support
Red
On for fi ve seconds,
then off
Power on for SAS/SATA/NVMe with
RSTe support
Red
Blinking at 4 Hz
Identify drive for SAS/SATA/NVMe with
RSTe support
Green
Solid On
Safe to remove NVMe device
Amber
Blinking at 1 Hz
Attention state—do not remove NVMe
device
Information LED
See the following table for the status shown by this LED.
Information LED
Status
Description
Continously on and red
An overheat ocondition has occured. (This may be caused by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative power supply.
Solid blue
Local UID has been activated. Use this function to locate the server in a rack
environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this function to locate the server from a
remote location.
Summary of Contents for Supero SUPERSERVER 2027PR-DNCFR
Page 1: ...SUPERSERVER 2027PR DNCR 2027PR DNCFR 2027PR DNCTR SUPER USER S MANUAL Revision 1 0...
Page 5: ...v SUPERSERVER 2027PR DNCR DNCFR DNCTR USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 2027PR DNCR DNCFR DNCTR USER S MANUAL...
Page 34: ...SUPERSERVER 2027PR DNCR DNCFR DNCTR USER S MANUAL 3 4 Notes...
Page 84: ...5 30 SUPERSERVER 2027PR DNCR DNCFR DNCTR USER S MANUAL Notes...
Page 102: ...6 18 SUPERSERVER 2027PR DNCR DNCFR DNCTR USER S MANUAL Notes...
Page 140: ...A 2 SUPERSERVER 2027PR DNCR DNCFR DNCTR USER S MANUAL Notes...