Seven heavy duty fans provide cooling for the chassis. These fans circulate air
through the chassis as a means of lowering the chassis internal temperature.
4-7 System Fans
Figure 4-17: Rear System Fans
Release Tab
Replacing a System Fan
If necessary, open the chassis while the power is running to determine which
1.
fan has failed. (Never run the server for an extended period of time with the
chassis open.)
Turn off the power to the system and unplug the system from the outlet.
2.
Press the fan release tab to lift the failed fan from the chassis and pull it
3.
completely from the chassis.
Place the new fan into the vacant space in the housing while making sure the
4.
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
Power up the system and check that the fan is working properly before re-
5.
placing the chassis cover.
Figure 4-16: Front System Fan
Release Tab
Release Tab