background image

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes 

no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update 

or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: 

For the most up-to-date version of this manual, please see our website at 

www.supermicro.com

.

Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual 

at any time and without notice. This product, including software and documentation, is the property of Supermicro and/

or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except 

as expressly permitted by the terms of said license.

IN  NO  EVENT  WILL  Super  Micro  Computer,  Inc.  BE  LIABLE  FOR  DIRECT,  INDIRECT,  SPECIAL,  INCIDENTAL, 

SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT 

OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER 

MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED 

OR  USED  WITH  THE  PRODUCT,  INCLUDING  THE  COSTS  OF  REPAIRING,  REPLACING,  INTEGRATING, 

INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.

Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the 

State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution 

of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product. 

FCC Statement: This equipment has been tested and found to comply with the limits for a Class A or Class B digital 

device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference when the equipment is operated in industrial environment for Class A device or in residential 

environment for Class B device. This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with 

radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in 

which case you will be required to correct the interference at your own expense.

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only 

to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. 

See 

www.dtsc.ca.gov/hazardouswaste/perchlorate

”.

 

 

 

 

 

 

WARNING: This product can expose you to chemicals including 
lead, known to the State of California to cause cancer and birth 
defects or other reproductive harm. For more information, go 
to www.P65Warnings.ca.gov. 

 

The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, 

nuclear  facilities  or  systems,  aircraft,  aircraft  devices,  aircraft/emergency  communication  devices  or  other  critical 

systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic 

property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products 

for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully 

indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and 

proceedings of any kind arising out of or related to such ultra-hazardous use or sale.

Manual Revision 1.0b

Release Date: October 13, 2020 

mk

Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this 

document. Information in this document is subject to change without notice. Other products and companies referred 

to herein are trademarks or registered trademarks of their respective companies or mark holders.

Copyright © 2020 by Super Micro Computer, Inc.

 

All rights reserved.

 

Printed in the United States of America

Summary of Contents for SBM-25G-P10

Page 1: ...USER S MANUAL Revision 1 0b SBM 25G P10 Pass Thru Module...

Page 2: ...ss A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s in...

Page 3: ...nfo http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support supermicro com This manual may be periodically updated without no...

Page 4: ...g for SBE 820J with Four Pass Thru Modules Installed 12 Mapping for SBE 610J with Four Pass Thru Modules Installed 14 Mapping for SBE 414E with Two Pass Thru Modules Installed 15 5 Firmware and Config...

Page 5: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Page 6: ...enclosure The Pass Thru module leverages the existing network infrastructure to provide direct network connectivity between the blade servers and the external Top of Rack ToR switches using five exter...

Page 7: ...Front View QSFP28 Port split Status LED Module Front Features Item Description QSFP28 Ports Ports accept QSFP28 Direct Attach Cable DAC or QSFP28 transceiver modules Console Port RJ45 usually for debu...

Page 8: ...odule can be connected to any computer using the RS 232 Console port This is generally used to collect debug logs for the Supermicro Technical Support team The computer COM port settings should be Bau...

Page 9: ...nal Ports Blade Enclosure 4 Port Mapping The port mapping between the blade server and the switch external port varies depending on the model of the enclosure The on board dual port NIC card and the o...

Page 10: ...ables In the tables below the following identifiers are used Module Slot A1 A2 B1 and B2 refer to the modules and their slot number Shown for the SBE 610J enclosure with four pass thru modules Figure...

Page 11: ...nted on their 4xSFP28 split cables with either A B C and D or 1 2 3 and 4 to represent the cable The column addresses both the specifications with example A 1 A or 1 External Port Q1 to Q5 refer to th...

Page 12: ...C 2 A2 Q4 13 A 1 Mezzanine NIC 3 B1 Q2 8 D 4 Mezzanine NIC 4 B2 Q2 8 D 4 A5 On Board NIC 1 A1 Q5 17 A 1 On Board NIC 2 A2 Q3 11 C 3 Mezzanine NIC 3 B1 Q3 10 B 2 Mezzanine NIC 4 B2 Q3 10 B 2 A6 On Boar...

Page 13: ...Q1 1 A 1 Mezzanine NIC 4 B2 Q2 7 C 3 B5 On Board NIC 1 A1 Q3 12 D 4 On Board NIC 2 A2 Q3 12 D 4 Mezzanine NIC 3 B1 Q1 3 C 3 Mezzanine NIC 4 B2 Q3 9 A 1 B6 On Board NIC 1 A1 Q3 10 B 2 On Board NIC 2 A...

Page 14: ...d NIC 2 A2 Q2 7 C 3 Mezzanine NIC 3 B1 Q1 4 D 4 Mezzanine NIC 4 B2 Q1 4 D 4 A5 On Board NIC 1 A1 Q2 6 B 2 On Board NIC 2 A2 Q2 6 B 2 Mezzanine NIC 3 B1 Q2 5 A 1 Mezzanine NIC 4 B2 Q2 5 A 1 A6 On Board...

Page 15: ...A2 Q3 11 C 3 A5 On Board NIC 1 A1 Q3 10 B 2 On Board NIC 2 A2 Q3 10 B 2 A6 On Board NIC 1 A1 Q3 9 A 1 On Board NIC 2 A2 Q3 9 A 1 A7 On Board NIC 1 A1 Q2 8 D 4 On Board NIC 2 A2 Q2 8 D 4 A8 On Board NI...

Page 16: ...pgrade Note Contact Supermicro Technical Support to get the appropriate configuration file or in case the external ports link does not come up Instructions to Upload Config File Upgrade 1 Log in to th...

Page 17: ...e available in a TFTP server for download File Name bmb25gp10_cfg dat Note The configuration file name should be exactly the same as above as it is applied to the pass thru module Figure 11 File Upgra...

Page 18: ...ut cables Console Port One RJ45 based Physical and Environmental Specifications Weight 1 99lbs 0 902Kg Dimensions 6 1 2 x 10 9 16 x 1 1 2 Temperature Operating 0 C to 45 C 32 F to 113 F Humidity Opera...

Reviews: