16
SBM-25G-P10 User's Manual
Figure 8. CMM Switch Module Page
5 Firmware and Configuration File Upload
Depending on the vendor and model of the external Top of Rack switch, an appropriate
configuration file must be uploaded to the module to enable the external QSFP28 uplinks. This
can be done using the CMM Web interface (version 3.55 or later is required). The procedure
below applies for both configuration file and firmware upgrade.
Note
: Contact Supermicro Technical Support to get the appropriate configuration file or in
case the external ports link does not come up.
Instructions to Upload Config File/Upgrade
1.
Log in to the CMM web interface and, from the left pane, select
Switch Module
to view
the switch summary page. Then click the pass-thru module for which you want to update
the configuration file.
In this example we are using switch A1.
2.
Configure an IP address for the module. Scroll down to the
Switch Network Configuration
section to configure the IP address. The IP address can be static or DHCP. Click
Save
.
Figure 9. Get Module IP Address