Supermicro L2/L3 Switches Configuration Guide
40
The example below shows the commands used to configure the switch name.
SMIS# configure terminal
SMIS(config)#
device name switch1
switch1
(config)# end
switch1# show system information
Switch Name: switch1
Switch Base MAC Address: 00:30:48:e3:70:bc
SNMP EngineID: 80.00.08.1c.04.46.53
System Contact: http://www.supermicro.com/support
System Location: Supermicro
Logging Option: Console Logging
Login Authentication Mode: Local
Snoop Forward Mode: MAC based
Config Restore Status: Not Initiated
Config Restore Option: No restore
Config Restore Filename: iss.conf
Config Save IP Address: 0.0.0.0
Device Up Time: 0 days 0 hrs 1 mins 11 secs
Boot-up Flash Area: Normal
NTP Broadcast Mode: No
[NTP] ntp is disabled
Server Key Prefer
=============== ===== ======
Key # Key
======= ====================================
Time zone offset not set
1.6.2
Switch Contact
Supermicro switches provide an option to configure the switch in charge Contact details, usually an
email ID.
Follow the steps below to configure the switch contact.
Step Command
Description
Step 1
configure terminal
Enters the configuration mode.
Step 2
system contact <string - to use more than one
word, provide the string within double quotes>
Configures the switch contact.