5-8
SC836B JBOD Chassis Manual
Figure 5-6. Installing into a Rack
Sliding the Chassis onto the Rack Rails
Warning:
Mounting the system into the rack requires at least two people to
support the chassis during installation. Please follow safety recommendations
printed on the rails.
Installing the Chassis into a Rack
1. Extend the outer rails as illustrated above.
2. Align the inner rails of the chassis with the outer rails on the rack.
3. Slide the inner rails into the outer rails, keeping the pressure even on both
sides. When the chassis has been pushed completely into the rack, it should
click into the locked position.
4. Optional screws may be used to hold the front of the chassis to the rack.
Note:
The figure above is for illustrative purposes only. Always install servers to
the bottom of the rack first.
Caution:
Do not pick up the server with the front handles. They are designed
to pull the system from a rack only.