Chapter 5: Advanced Serverboard Setup
5-7
5-6
S
UPER
S
TORAGE
S
YSTEM 6047R-E1R36N User's Manual
Warning:
You can only install the CPU to the socket in one direction. Make sure that
the CPU is properly inserted into the socket before closing the load plate. If it doesn't
close properly, do not force it as it may damage your CPU. Instead, open the load
plate again and double-check that the CPU is aligned properly.
8. Close the load plate. Lock the
lever labeled 'Close 1st', then lock
the lever labeled 'Open 1st'. Use
your thumb to gently push the
load levers down until the lever
locks.
OPEN 1st
OPEN 1st
Lever Lock
Push down and
lock the lever
labeled 'Open
1st'.
Push down and lock the level
labeled 'Close 1st'.
Gently close
the load plate.
OPEN 1s
t
Serverboard
Screw#1
Screw#2
Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die - the required
amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the serverboard and the heatsink bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(to prevent possible damage to the CPU, do not over-tighten the screws).
4. Finish the installation by fully tightening all four screws.
Mounting Holes
Screw#4
Summary of Contents for 6047R-E1R36N
Page 1: ... SUPER STORAGE SYSTEM 6047R E1R36N SUPER USER S MANUAL 1 1 ...
Page 17: ...3 4 SUPERSTORAGESYSTEM 6047R E1R36N User s Manual Notes ...
Page 28: ...4 20 SUPERSTORAGESYSTEM 6047R E1R36N User s Manual Notes ...
Page 70: ...7 32 SUPERSTORAGESYSTEM 6047R E1R36N User s Manual Notes ...
Page 72: ...A 2 SUPERSTORAGESYSTEM 6047R E1R36N User s Manual Notes ...