Installing the Server into the Rack
Locate the front and rear brackets that on both ends of the outer chassis rail. These
brackets sit perpendicular to the rail and are used to attached the rail to the rack.
Secure the front bracket to the rack with two screws and the rear bracket to the rack
with four screws using the appropriate screws and washers included in the hardware
kit (see Figure 2-3). You may need to adjust the rail to match the depth of the rack.
Repeat the same steps to install the other outer rail to the rack.
You are now ready to install the server into the rack. Slide the chassis into the rack
as shown in Figure 2-4. The chassis may not slide into the rack smoothly or easily
when installed the fi rst time. Some adjustment to the slide assemblies might be
needed for easier installation.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". You'll need to release the safety taps on both sides of the chas-
sis in order to completely remove the chassis out of the rack.
Figure 2-3. Assembling the Rack Rails
Screws
Screws
Front Bracket
Rear Bracket
Summary of Contents for 6037R-E1R16L
Page 1: ... SUPER STORAGE SYSTEM 6037R E1R16L SUPER USER S MANUAL 1 0 ...
Page 5: ...Notes Preface v ...
Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Rack ...
Page 22: ...2 8 SUPERSTORAGESYSTEM 6037R E1R16L User s Manual Notes ...
Page 26: ...3 4 SUPERSTORAGESYSTEM 6037R E1R16L User s Manual Notes ...
Page 62: ...5 32 SUPERSTORAGESYSTEM 6047R E1R24L User s Manual Notes ...
Page 74: ...6 12 SUPERSTORAGESYSTEM 6037R E1R16L User s Manual Notes ...
Page 108: ...A 2 SUPERSTORAGESYSTEM 6037R E1R16L User s Manual Notes ...