B-2
S
UPER
S
ERVER 6027R-73DARF User's Manual
Weight
57 lbs. (25.9 kg.)
System Cooling
Three 8-cm system cooling fans
Note:
The system cooling fans are redundant, hot-plug.
System Input Requirements
AC Input Voltage: 100 - 240V AC auto-range
Rated Input Current: 9 - 3.5A max
Rated Input Frequency: 50 to 60 Hz
Power Supply Output
Rated Output Power: 740 Watt (Part# PWS-741P-1R)
Rated Output Voltages: +12V (61.7A), +5Vsb (4A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
0º to 47º C (32º to 116º F) with certain confi gurations/workload environments
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Note:
The system power supplies are redundant, hot-plug.
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate”
Summary of Contents for 6028R-WTR
Page 1: ...SUPERSERVER 6028R WTR 6028R WTRT SUPER USER S MANUAL Revision 1 0...
Page 5: ...Notes Preface v...
Page 10: ...SUPERSERVER 6028R WTR T USER S MANUAL x Notes...
Page 26: ...SUPERSERVER 6027R 73DARF User s Manual 3 4 Notes...
Page 78: ...5 32 SUPERSERVER 6028R WTR T USER S MANUAL Notes...
Page 86: ...6 8 SUPERSERVER 6027R 73DARF User s Manual Notes...
Page 118: ...7 32 SUPERSERVER 6028R WTR T USER S MANUAL Notes...
Page 120: ...A 2 SUPERSERVER 6028R WTR T USER S MANUAL Notes...