Chapter 6: Advanced Chassis Setup
6-3
6-3 System
Fans
Three 4-cm fans provide the cooling for the 5015M-T/5015M-T+. Each fan unit is
actually made up of two fans joined back-to-back, which rotate in opposite direc-
tions. This counter-rotating action generates exceptional airfl ow and works to
dampen vibration levels. These fans can adjust their speed according to the heat
level sensed in the system, which results in more effi cient and quieter fan operation.
Fan speed is controlled by a setting in BIOS (see Chapter 7). Each fan in a set
has its own separate tachometer. An air shroud is also included with the system
to optimize airfl ow.
Note:
It is very important that the chassis top cover is properly installed for the
airfl ow to circulate properly through the chassis and cool the components.
System Fan Failure
If a fan fails, the remaining fans will ramp up to full speed and the overheat/fan
fail LED on the control panel will blink on and off. Replace any failed fan at your
earliest convenience with the same type and model (the system can continue to
run with a failed fan). Remove the top chassis cover (refer to page 6-7) while the
system is still running to determine which fan unit has failed, then power down
the system to replace it. Removing the power cord(s) is also recommended as a
safety precaution.
Replacing System Cooling Fans
1.
Removing a fan
With the system powered down, fi rst unplug the failed fan cable from the mother-
board. Grasp the failed fan unit and lift it out of the chassis.
2.
Installing a new fan
Replace the failed fan with an identical 4-cm, 12 volt fan (available from Supermicro:
p/n FAN-0087). At the bottom of each fan unit there are four small rubber pieces
that help position the fan into place in the chassis. Remove these from the failed
fan and attach them to the new fan (new fans do not include this piece). Then place
the new fan in the housing with the fan wiring toward the motherboard. Reconnect
the fan wiring to the same fan header you removed it from. Power up the system
and check that the fan is working properly and that the LED on the control panel
has turned off. Finish by replacing the chassis cover.
Summary of Contents for 5015M-T
Page 1: ...SUPER SUPERSERVER 5015M T SUPERSERVER 5015M T USER S MANUAL Revision 1 0c...
Page 5: ...v Preface Notes...
Page 10: ...x Notes SUPERSERVER 5015M T 5015M T User s Manual...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 30: ...3 4 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 58: ...5 24 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 66: ...6 8 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 88: ...7 22 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 90: ...A 2 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 96: ...B 6 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 114: ...C 18 SUPERSERVER 5015M T 5015M T User s Manual Notes...
Page 118: ...D 4 SUPERSERVER 5015M T 5015M T User s Manual Notes...