Chapter 2: Server Installation
2-5
Figure 2-2. Installing Chassis Rails
(with optional front bezel shown)
Installing the Chassis Rails
Position the fi xed chassis rail sections you just removed along the side of the
1020A-8 making sure the screw holes line up. Note that these two rails are left/right
specifi c. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat
this procedure for the other rail on the other side of the chassis. You will also need
to attach the rail brackets when installng into a telco rack.
Locking Tabs:
As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Installing the Rack Rails
Determine where you want to place the 1020A-8 in the rack. (See Rack and Server
Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail guide assemblies
at the desired location in the rack, keeping the sliding rail guide facing the inside
of the rack. Screw the assembly securely to the rack using the brackets provided.
Attach the other assembly to the other side of the rack, making sure both are at
the exact same height and with the rail guides facing inward.
Summary of Contents for 1020A-8
Page 1: ...A Server 1020A 8 USER S MANUAL 1 0...
Page 5: ...v Preface Notes...
Page 10: ...x Notes A Server 1020A 8 User s Manual...
Page 16: ...1 6 A Server 1020A 8 User s Manual Notes...
Page 86: ...7 20 A Server 1020A 8 User s Manual Notes...
Page 88: ...A 2 A Server 1020A 8 User s Manual Notes...