background image

 

1

4.3.5 Control board wiring

 

VR1

VR1

VR2

VR2

VR3

VR3

U1

U1

ON

ON

OFF

OFF

J9

J9

LRN

LRN

K4

K4

UV2

UV2

J8

J8

RL6

RL6

J1

J1

J4

J4

UV4

UV4

C3

C3

J2

J2

BAT+

BAT+

F1

F1

D6

D6

DKC500DC.PCB

DKC500DC.PCB

2015.01.05

2015.01.05

R8

R8

R9

R9

N1

N1

R

L1

R

L1

R

L2

R

L2

D

15

D

15

C

20

C

20

P

WR

P

WR

SW1

SW1

U4

U4

U3U3

C2C2

J10

J10

J7

J7

C23

C23

+

A

LM-

+

A

LM-

5

6

7

M

OT

M

OT

P

O

WER

P

O

WER

1

2

3

5

7

9

OPOP

C

OM

C

OM

CLCL

4

3

2

1

M

24VAC

24VAC

24VDC

24VDC

Learning

Learning button

button

OP

OP

CL

CL
COM

COM

COM

COM

Alarm

Alarm lamp

lamp

Stop

Stop button

button

Close

Close button

button

Open

Open button

button

COM

COM

24VDC

24VDC motor

motor

Infrared

Infrared sensor

sensor

Storage

Storage battery

battery

 

Figure 10 

 

Transformer Power Input Connection 

 

              

C3

C3

J2

J2

BAT+

BAT+

F1

F1

D6

D6

DKC500DC.PCB

DKC500DC.PCB

2015.01.05

2015.01.05

R8

R8

R9

R9

C23

C23

P

O

W

E

R

P

O

W

E

R

Transformer

Transformer input

input 220VAC

220VAC

Transformer

Transformer output

output 24VAC

24VAC

 

 
                                   

Figure 11 

Summary of Contents for SSLG-2 800DC

Page 1: ...SSLG 2 800DC Sliding Gate Opener User Manual...

Page 2: ......

Page 3: ...the actual gate opener type The indicator light on the remote control unit will flicker when its button is pressed Main engine and gate can be unlocked with a disengagement wrench and the gate can be...

Page 4: ...e 1 2 Manual release key 2 3 A B C D A B C D Remote control 2 4 Magnetic limit switch accessories box 1 4 1 Magnetic limit switch block 1 4 2 Limit switch block mounting screw M6X18 4 4 3 Foundation b...

Page 5: ...on head bolt M8 60 4 3 Technical parameters Model DKC500DC DKC800DC Power supply 220V 50Hz 110V 60Hz 220V 50Hz 110V 60Hz Motor power 150W 170W Gate moving speed 11 13m min 16 18m min Maximum weight of...

Page 6: ...e weight less than 500kg 800kg and length of the sliding gate less than 8m The drive mode adopts the rack and gear transmission This gate opener must be installed inside the enclosure or yard for prot...

Page 7: ...installing the gate opener Cable installation In order to guarantee the normal operation of the gate opener and protect the cables from damages please bury the motor power cable and controlling cable...

Page 8: ...spot c Please unlock the main engine before installation the unlock method is remove the rubber key cover insert the key and open the manual release bar till it rotates by 90 as shown in Figure 5 Then...

Page 9: ...the gate from running out of the rail or safety range Please make sure that the main engine and its components have good mechanical properties and the gate can be operated flexibly when manually move...

Page 10: ...ic limit switch The installation position of magnetic limit switch is shown in Figure 8 20mm Gate Gate Magnets Magnets Magnetic Magnetic limit limit switch switch stop stop block block Gear Gear rack...

Page 11: ...adjust please refer to the section 4 3 5 DIP switch adjustment to change the door opening direction through the DIP switch 5 Note After first installed or Re power up please drive one opening and clo...

Page 12: ...OP COM COM CL CL 4 3 2 1 M 24VAC 24VAC 24VDC 24VDC Learning Learning button button OP OP CL CL COM COM COM COM Alarm Alarm lamp lamp Stop Stop button button Close Close button button Open Open button...

Page 13: ...ion Red wire to top black wire to bottom J7 Terminal 1 Gate open control button N O 2 Gate close control button N O 3 Stop control button N O 4 Control button common terminal J8 Terminal 24V DC cautio...

Page 14: ...ly control OPEN STOP CLOSE STOP 4 OFF External button switch is single button mode connect to 1 and 4 of J7 ON External button switch is three button mode 5 Left and Right installation setting OFF Rig...

Page 15: ...remote control control Single Single button button mode mode remote remote control control A B C D OPEN OPEN A B C D CLOSE CLOSE STOP STOP CLOSE CLOSE OPEN OPEN STOP STOP Pedestrian Pedestrian mode mo...

Page 16: ...button on the remote control is for pedestrian mode press the button while the door is closed it will open for 1 meter which is for pedestrian only Battery connection C3 C3 J2 J2 BAT BAT F1 F1 D6 D6 D...

Page 17: ...of safety each gate is suggested to be equipped with infrared protector and regular inspection is required Before installation and operation of the gate opener please read all instructions carefully...

Page 18: ...ng 3 According to the actual situation to adjust the motor or the gate Not stop at the limit position when opening closing 1 The limit direction is wrong 2 The mounting of magnetic limit switch with p...

Page 19: ...ter the date of invoice 3 Without unauthorized dismantling any product broken or damage due to quality problem we ll offer the repair service for free or replace for free 4 The malfunction and damaged...