Superior WRT4826WH Installation And Operation Instructions Manual Download Page 28

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

28

Tubinox® (or Projet

®

 SS) Chimney **

For Relining a Masonry Chimney, 7" Diameter

Listed to ULC-S635M, JL-1777 and ULC-S640M at 2100° F

Description

Cat./ Part No.

Length 6", 7LL6

7LL6

Length 12", 7LL12

7LL12

Length 24", 7LL24

7LL24

Length 36", 7LL36

7LL36

Length 48", 7LL48

7LL48

Adjustable Length (7" to 11"), 7L7A

7L7A

Split Base Tee, 7LT

7LT

Tee Cap, 7TCS

7TCS

Twist Lock Tee Cap, 7LTC

7LTC

Elbow 30°, 7LE30

7LE30

Elbow 45°, 7LE45

7LE45

Elbow 90°, 7LE90

7LE90

Rain Termination Cap (regular), 7LCS

7LCS

Rain Termination Cap (deluxe), 7LCC

7LCC

Supports

Top Support, 7LST

7LST

Support Assembly, 7LSA

7LSA

Interior Support, 7LSB

7LSB

Adaptor Flexible Pipe (male), 7LAAM

7LAAM

Adaptor Flexible Pipe (female), 7LAAF

7LAAF

Stainless Steel Flex - 5 Ft. Long, 7LLFLEX 

7LLFLEX

Adjustable Insulated Wall Radiation Shield 6" to 12", 7LRSMI

7LRSMI

Adaptors to Masonry Chimney

Masonry Chimney Adaptor, 45º, BISPMA, 

CANADA ONLY

BISPMA

30° Adaptor for Masonry Chimney, BISPMA30

BISPMA30

SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS

The components listed below must be ordered from Security Chimneys International™.  Contact your Security Chimneys Distributor or Dealer for ordering 
information.  

Gravity Kit Accessories

Elbow 90º, 8” dia., 7B26ZE90

7B26ZE90

Elbow 45º, 8” dia., 7B26ZE45

7B26ZE45

Telescopic length, 8” dia. (15” to 26”), 7B26ZLA

7B26ZLA

Adjustable length 8” dia (2” - 5”), 7B26ZL2A

7B26ZL2A

Wall radiation shield, 8” I.D., 7B26ZR

7B26ZR

Black grill with support, 7B30ZO

7B30ZO

Brass grill (for 7B30ZK), 7B30ZGB

7B30ZGB

Length one (1) feet, 8KL1

8KL1

Length two (2) feet, 8KL2

8KL2

Length three (3) feet, 8KL3

8KL3

Length four (4) feet, 8KL4

8KL4

Length fi ve (5) feet, 8KL5

8KL5

**  

Alternate brand rigid stainless liner or stainless fl ex may be substituted but 
must be listed to UL-1777 for US application and ULC-S635 for existing 
masonry or ULC-S640M for new masonry applications in Canada. The steel 
rigid or fl ex liner must be rated at 2100º F (1100º C).

Summary of Contents for WRT4826WH

Page 1: ...ith an adjustable safety gate or barrier screen Wood Burning Fireplaces P N 900085 00 REV B 06 2016 WRT4826WH WRT4826WH This installation manual will enable you to obtain a safe efficient and dependab...

Page 2: ...structionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING TheWRT4826WHfireplacemust be installed with an outside...

Page 3: ...18 ACBI Chimney Installation Instructions Page 19 Offset Chimney Installation Page 20 Angled Wall Radiation Shield Page 21 Chimney Support Installation Page 22 Chimney Chase And Multiple Terminations...

Page 4: ...tering the combustor have to be higher than 500 F 260 C That is why the unit is equipped with a by pass damper that allows the draft air to by pass the catalytic combustor Opening the by pass damper c...

Page 5: ...ors includingchimney length and the moisture content of the wood This method of burning should be used only after operating the WRT4826WH fireplace with the air control opened to produce a hot fire fo...

Page 6: ...including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulations to operate wood heaters in a man...

Page 7: ...c tionsinthismanual orifthecatalyticelement is deactivated or removed Creosote When wood is burned slowly it produces tar and other organic vapors which combine with expelledmoisturetoformablackdeposi...

Page 8: ...e combustor in a partially open and partially closed position after a hot fire has been started Burn hardwoods Masking Soot See Photo 8 Combustor has not maintained a light off Burning coal will cause...

Page 9: ...s deep in your firebox andwhenthefirehasburneddownand cooled removeexcessashes Leaveanashbed approximately1inchdeeponthefireboxbottom to help maintain a hot charcoal bed Remove ashes only when the fir...

Page 10: ...e 9 Figure 8 Figure 9 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO PEEL CAUTION DONOTALLOWWINDOWCLEANER TO GET IN CONTACT WITH DOOR GASKET OR PAINT ON FACADE OR...

Page 11: ...The WRT4826WH fireplace may be installed directly on a combustible floor The supplied safetymetalstripmustbepositionedasfollows One half under the front of the fireplace and the otherhalfmustextendon...

Page 12: ...llustrations and photographs are nottoscale consultinstallationinstructions Product designs materials dimensions specifications colorsandpricesaresubjectto change or discontinuance without notice Allf...

Page 13: ...bustibles around chimney components required NOTE Blown or fill type insulation materials must not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcod...

Page 14: ...t 38 and a height of 54 from the base of the appliance see Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Figure 14...

Page 15: ...68 1727 mm Maximum length See Figure 17 The height of the louver must be measured fromthebaseoftheWRT4826WHfireplace to the middle point of the louver When installing the double outlet system the hota...

Page 16: ...the hot air ducts to a central heating system Malfunction of the heating system s fan will cause the furnace duct to overheat A furnace duct is only single wall and not double wall as is required for...

Page 17: ...he basement or garage 4 The air intake register should be installed where it is not likely to be blocked by snow or exposed to extreme wind and well away fromautomobileexhaustfumes gasmeters and other...

Page 18: ...tional Ltd 7 diameter chimney systems models ACBI or ASHT or S2100 or DuraVent model DuraTech DTC chimney systems NOTE Use of ACBI chimney with these fireplaces require the use of a starter section us...

Page 19: ...20 feet and at the roof level installauniversalsupportfasteningthestrapsto thesurroundingjoists ASHT Installsupport as required see Chimney Support Installation Section on Page 22 4 Puttheroofflashing...

Page 20: ...h together It is recommended to use three 3 metalscrews Ifpenetratingawall use a wall radiation shield 3 Use another elbow to turn the chimney vertically ACBI Lock it to the chimney Fastenthestrapsatt...

Page 21: ...8 mm Chimney 7 Elbow Deviation Length ONE LENGTH BETWEEN ELBOWS TWO LENGTHS BETWEEN ELBOWS 8 12 18 24 36 48 8 36 12 48 18 48 24 48 36 48 Secure Temp ASHT DuraTech DTC 15 Deviation 3 5 16 84 mm 4 5 16...

Page 22: ...lightly lift the chim neysystemsotheweightwilllieonthesupport notonthefireplacetoreduceexpansionnoises This support has two possible uses 1 For ASHT it must be used on a roof to support the chimney 2...

Page 23: ...e ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry ch...

Page 24: ...mney for Relining Masonry Chimneys Tubinox chimney or Projet SS 7 diameter with adaptor for installation in a masonry chimney NOTES Projet Nova Temp HT6000 is equivalent to S2100 Projet Nova Temp HT61...

Page 25: ...adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2 clamps BISAF BISAF Thermopile gauge and label replacement J8004 CLEARANCE TO COMBUSTIBLES The following clearances m...

Page 26: ...alling ACBI Chimney Starter Section w Air Intake 7 Dia ACBI7SBA ACBI7SBA Offset Starter Section 30 7 Dia ACBI7SBA30 ACBI7SBA30 Outside Air Kit The following components are required if installing ACBI...

Page 27: ...R Storm Collar 7FC 7FC DuraTech DTC 1 High Temp Insulated Stainless Steel Chimney 7 I D and 11 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT and CAN ULC S629 Description Part Cat No Len...

Page 28: ...ry Chimney Masonry Chimney Adaptor 45 BISPMA CANADA ONLY BISPMA 30 Adaptor for Masonry Chimney BISPMA30 BISPMA30 SECURITY CHIMNEYS PARTS AND COMPONENTS LISTS The components listed below must be ordere...

Page 29: ...use with approved fuels listed in the Operation Manual provided with the product This includes burning such replace fuels as wood and natural or propane gas Fuel products with abnormal burning charac...

Page 30: ...PARTS See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shippe...