background image

Superiorfireplaces.US.com

127055-01E

12

A gas line or gas log lighter may be installed for the purpose of 
installing a vented or vent-free decorative gas appliance incorporat-
ing an automatic shutoff device and complying with the Standard 
for Decorative Gas Appliances for Installation in Vented Fireplaces, 

ANSI฀Z21.60฀or฀American฀Gas฀Association฀draft฀requirements฀for฀

Gas฀Fired฀Log฀Lighters฀for฀Wood฀Burning฀Fireplaces,฀Draft฀NO.฀4฀

dated August, 1993.

If฀ you฀ wish฀ to฀ install฀ an฀ unvented฀ (vent-free)฀ gas฀ log฀ set,฀ only฀

unvented gas log sets which have been found to comply with the 

standard฀for฀unvented฀room฀heaters,฀ANSI฀Z21.11.2฀are฀to฀be฀installed฀

in this fireplace.

Gas line hook up should be done by your supplier or a qualified 
service person.

Note:

 Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.
1.  Remove knockout indentation on refractory or firebrick wall 

located above refractory hearth floor. Knockout indentation must 
be firmly tapped with any solid object, such as a 1/2" dowel, until 

it฀is฀released.฀Remove฀fragmented฀portions฀of฀refractory฀(see฀

Figure฀19,฀page฀13).

2.  Remove gas line cover plate located on either side of fireplace and 

pull out insulation from gas line conduit sleeve. Save insulation 
for reuse.

3.  Run a 1/2" black iron gas line into fireplace through rear at 

gas฀line฀conduit฀sleeve฀(if฀using฀a฀raised฀platform,฀add฀height).฀

Provide sufficient gas line into fireplace chamber for fitting 

OPTIONAL GAS LINE INSTALLATION

VENTING INSTALLATION 

Continued

connection฀(see฀Figure฀20,฀page฀13).

฀ Note:฀Secure฀incoming฀gas฀line฀to฀wood฀framing฀to฀provide฀rigidity฀

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal 

any gaps between gas line and refractory knockout hole with 
refractory cement or commercial furnace cement. Install gas 
appliance or cap off gas line if desired.

 CAUTION: All gas piping and connections must be 

tested for leaks after installation is completed. After 
ensuring that gas valve is on, apply soap and water 
solution to all connections and joints. Bubbles forming 
show a leak. Correct all leaks at once. DO NOT USE 
AN OPEN FLAME FOR LEAK TESTING AND DO NOT 
OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 
LEAK TESTING SHOULD BE DONE BY A QUALIFIED 
SERVICE PERSON.

Note: 

An฀IHP฀hood฀must฀be฀installed฀when฀using฀an฀unvented฀gas฀

log฀set฀(see฀

Accessories

฀on฀page฀19).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with chimney removed.

30E-12DMO-8DMR

30E-12DMO-8DMR

30E-12DMO-8DMR

EFFECTIVE HEIGHT 
OF TERMINATION CAP

EFFECTIVE HEIGHT 
OF TERMINATION CAP

EFFECTIVE HEIGHT 
OF TERMINATION CAP

EFFECTIVE HEIGHT 
OF TERMINATION CAP

MINIMUM
HEIGHT

14 

1

/

2

  

FT.

14 

1

/

2

  

FT.

MINIMUM

UP TO 
6FT. MAX.

UP TO 
6FT. MAX.

HEIGHT

STARTER
SECTION

STARTER
SECTION

MIN. HEIGHT 
OF 22 FT. (WITH
2 ELBOW SETS)
MAX. HEIGHT OF
50 FT.

MAX. HEIGHT
50 FT.
(ANY SYSTEM)

STARTER
SECTION

Figure 21 - Typical Residential Installations

Summary of Contents for WRE3042RH

Page 1: ...TH PRODUCTS LLC hood must be installed when using a vent free log heater see Ac cessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department...

Page 2: ...Use of any component part not manufactured or approved by IHP in combination with an IHP ireplace system Proper installation is the most important step in ensuring safe and continuous operation of th...

Page 3: ...ls used to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbo...

Page 4: ...COMBUSTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STA...

Page 5: ...um Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the ireplace to the lue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe...

Page 6: ...of Combustible Materials Fireplace Opening Non Combustible Materials Below Top Spacer Upper Section of Fireplace DRAIN PAN DP42 For outdoor installations the fireplace enclosure must allow for adequat...

Page 7: ...ists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consider...

Page 8: ...ead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be us...

Page 9: ...6 Max 6 Max 6 Max 6 Max 6 Max Ceiling Support Pipe 12S 8DM A B C FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to e...

Page 10: ...Only Figure 11 Firestop Spacer with Attic Space Above Ceiling NOTICE The installation of a firestop thimble FST30 or 38FST is recommended when negotiating a joist and to prevent intrusion from insula...

Page 11: ...erial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of lashing see Figure 14 Use SC1 for all r...

Page 12: ...ne conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figu...

Page 13: ...ass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BO...

Page 14: ...nes instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer Access Panel OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer REPLAC...

Page 15: ...red White Brick 1 J4147 Rear Refractory Textured White Herringbone 1 J4072 Rear Refractory Textured Red Brick 1 J4146 Rear Refractory Textured Red Herringbone 1 12 J4506 Bottom Rear Refractory White B...

Page 16: ...1 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS WRE3042WH WRE3042RS WRE3042RH MODEL NO CATALOG NO WRE3042WS F045...

Page 17: ...ght Refractory Brick Liner 1 11 See Page 15 Rear Refractory Brick Liner 1 12 See Page 15 Bottom Rear Refractory Liner 1 13 See Page 15 Bottom Front Refractory Liner 1 14 J3972 Firebox Support Leg 4 15...

Page 18: ...Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Se...

Page 19: ...Section F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with...

Page 20: ...Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chim...

Page 21: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 22: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 23: ...e subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with ab...

Page 24: ...e colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127055 01 Rev E 10 2015 P127055 01 WARRANTY KEEP THIS WARRANTY 1508 Elm Hil...

Reviews: