VENTING INSTALLATION 

Continued

CHASE INSTALLATIONS

Instructions for chase installations are included with chase style ter-
mination chosen. In a multiple chase installation, be sure to provide 
adequate distance between terminations to prevent smoke spillage 
from one termination to another. We suggest that terminations be 
separated at least 24", center to center and stacked at a vertical height 

difference฀of฀18"฀(see฀Figure฀16).

Note:

 If a decorative shroud is to be installed, contact manufacturer 

for specifications.

24" Min.

24" Min.

18" 

Min.

Figure 16 - Multiple Chase Installation

10'

2' Min.

10'

3' Min.

2' Min.

3' Min.

Level of 
Flue Gas 
Outlet

Figure 17 - 10 Foot Rule

10 FOOT RULE

All flue gas outlet chimney terminations must extend a minimum of 
3 feet in height above highest point where it passes through roof and 
must be at least 2 feet above highest point of the roof that is within 

a฀horizontal฀distance฀of฀10฀feet฀(see฀Figure฀17).

FINISHING FIREPLACE

Combustible฀materials,฀such฀as฀wallboard,฀sheet฀rock,฀drywall,฀ply

-

wood, etc., may make direct contact with sides and top around fire-
place face. It is important that combustible materials do not overlap 
face itself. Brick, glass, tile or other noncombustible materials may 
overlap front face provided they do not obstruct essential openings 
such as louvered slots. When overlapping with a noncombustible 
facing material, use only noncombustible mortar or adhesive.

Storm Collar Installation (SC1)

Place storm collar over pipe and slide down until it is snug against 

open฀edge฀of฀lashing฀(see฀Figure฀14).฀Use฀SC1฀for฀all฀round฀termina

-

tions. Apply waterproof caulk around perimeter of collar to provide 
a proper seal.

Figure 14 - Storm Collar

Chimney 
Pipe

Waterproof 
Caulk

Storm 
Collar

Flashing

Terminations/Spark Arrestor

Fireplace system must be terminated with listed round top or chase 
terminations. In any case, refer to installation instructions supplied 
with termination. Terminations approved for this fireplace are RT-

8DM฀and฀RLT-8DM฀that฀can฀be฀used฀for฀lashing฀or฀chase฀and฀ET-

8DM,฀ETO-8DM,฀ETL-8DM฀and฀ETLO-8DM฀for฀chase฀style฀termination฀

only. Figure 18 shows an RLT-8DM round top termination.

 CAUTION: Do not seal openings on the rooftop 

lashing.฀Follow฀the฀installation฀instructions฀provided฀

with the termination being used.

Terminations with 16" slip pipe sections are available. RTT-8DM, 
RTTL-8DM and RLTT-8DM are approved for flashing installations. 
When needed, these adjustable terminations may be used in combi-
nation with pipe assembly to achieve correct chimney height.

Note:

 In the rare instance there is a problem with side driven rain or 

wind฀or฀chimney฀is฀not฀drafting฀properly,฀an฀ADS-8DM฀(Anti-Draft฀

Shield)฀can฀be฀used฀with฀round฀terminations.

Attach Bracket 
Tabs to 
Outer Pipe 
(3 Places) 
Secure with 
Screws

RLT-8DM

Level of Flue 
Gas Outlet

Caulk

Collar

Flashing

Underlap Shingles 
Bottom Only

Figure 15 - Termination

Overlap 
Shingles Top 
and Sides

Flue Pipe 
of RLT-8DM 
Inside Inner 
Pipe of 
Chimney

Summary of Contents for WRE3042RH

Page 1: ...TH PRODUCTS LLC hood must be installed when using a vent free log heater see Ac cessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department...

Page 2: ...Use of any component part not manufactured or approved by IHP in combination with an IHP ireplace system Proper installation is the most important step in ensuring safe and continuous operation of th...

Page 3: ...ls used to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbo...

Page 4: ...COMBUSTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STA...

Page 5: ...um Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the ireplace to the lue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe...

Page 6: ...of Combustible Materials Fireplace Opening Non Combustible Materials Below Top Spacer Upper Section of Fireplace DRAIN PAN DP42 For outdoor installations the fireplace enclosure must allow for adequat...

Page 7: ...ists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consider...

Page 8: ...ead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be us...

Page 9: ...6 Max 6 Max 6 Max 6 Max 6 Max Ceiling Support Pipe 12S 8DM A B C FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to e...

Page 10: ...Only Figure 11 Firestop Spacer with Attic Space Above Ceiling NOTICE The installation of a firestop thimble FST30 or 38FST is recommended when negotiating a joist and to prevent intrusion from insula...

Page 11: ...erial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of lashing see Figure 14 Use SC1 for all r...

Page 12: ...ne conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figu...

Page 13: ...ass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BO...

Page 14: ...nes instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer Access Panel OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer REPLAC...

Page 15: ...red White Brick 1 J4147 Rear Refractory Textured White Herringbone 1 J4072 Rear Refractory Textured Red Brick 1 J4146 Rear Refractory Textured Red Herringbone 1 12 J4506 Bottom Rear Refractory White B...

Page 16: ...1 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS WRE3042WH WRE3042RS WRE3042RH MODEL NO CATALOG NO WRE3042WS F045...

Page 17: ...ght Refractory Brick Liner 1 11 See Page 15 Rear Refractory Brick Liner 1 12 See Page 15 Bottom Rear Refractory Liner 1 13 See Page 15 Bottom Front Refractory Liner 1 14 J3972 Firebox Support Leg 4 15...

Page 18: ...Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Se...

Page 19: ...Section F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with...

Page 20: ...Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chim...

Page 21: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 22: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 23: ...e subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with ab...

Page 24: ...e colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127055 01 Rev E 10 2015 P127055 01 WARRANTY KEEP THIS WARRANTY 1508 Elm Hil...

Reviews: