background image

www.SuperiorFireplaces.US.com

127020-01A

17

KEY 

NO. PART NO.

DESCRIPTION

QTY.

1

106638-01 Insulation Pan

1

2

**

Fireplace Top

1

3

106641-01

Fireplace Surround

1

4

106642-01

Air Rod Retainer

1

5

106643-01

Damper Rod Retainer

1

6

**

Firebox Bottom

1

7

**

Firebox Surround

1

8

**

Air Separator

1

9

See Below  Left Refractory

1

10

See Below  Right Refractory

1

11

See Below  Rear Refractory

1

12

See Below  Bottom Rear Refractory

1

13

See Below  Bottom Front Refractory

1

14

106683-01 Firebox Support Leg

4

15

106687-01 Damper Can Collar

1

16

106691-01

Screen Rod

2

17

**

Firebox Top Assembly

1

18

106703-01

Air Kit Door Assembly

1

19

**

Face Weldment

1

20

110892-01 Air Deflector

1

21

111327-01

Fireplace Top Insulation

1

22

107775-01

Access Panel

1

23

107854-01 Right Refractory Bracket

1

24

107854-02 Left Refractory Bracket

1

25

111028-01 Grate

1

26

11418

Push-On Nut

2

27

110890-01 Stainless Screen

2

28

16405

Collar Insulation

1

29

20023

Chimney Starter Collar

1

30

20027

Refractory Retainer

2

31

106539-02

Grate Retainer

2

32

111073-01

Door Stop

1

33

111204-01

Pivot Clip

2

34

20090

Spring Clip

2

35

20280

Top Spacer

4

36

21171

Conduit Plate Cover

4

37

21379

Gas Conduit

2

38

21380

Gas Conduit

2

PARTS AVAILABLE NOT SHOWN

106625-01

Home Owner’s Guide

1

20093

Ember Protector

2

** Not a field replaceable part

 

PARTS

WOOD BURNING FIREPLACE MODELS WRE3036WS, WRE3036WH, 

WRE3036RS AND WRE3036RH

This list contains replaceable parts used in your fireplace. When ordering parts, see 

Replace-

ment Parts

 on page 15 of this manual.

Summary of Contents for WRE3036WS

Page 1: ...ly or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unles...

Page 2: ...ife Refer to this manual for assistance or additional information Consultaqualifiedinstall er or local distributor IMPORTANT Check local codes before installing this fireplace Before beginning install...

Page 3: ...0 TO TOP SPACERS NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 9 125 11 435 14 437 41 250 37 41 35 21 8 32 5 14 25 2...

Page 4: ...tion must allow for proper clear ances see Figures 1 and 2 2 Consider a location where the fireplace will not be affected by drafts air condition ing ducts windows or doors 3 A location that avoids th...

Page 5: ...r of noncom bustible inorganic material having a thermal conductivity of K 0 84 BTU IN FT HR F or less at 1 thick For example if the material selected has a K factor of 0 25 such as glass fiber the fo...

Page 6: ...outlet of the termination Figure 5 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for W...

Page 7: ...s gained after fitting overlaps must be taken into consider ation lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is the actual measurable length of a part after two or mor...

Page 8: ...ow Offset Elbow 6 Max 6 Max 6 Max 6 Max 6 Max 6 Max Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S 8DM Return Elbow Figure 8 Ceiling Support Pipe 12S 8...

Page 9: ...urpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe passes through a framed opening into a living space above the firestop must b...

Page 10: ...6 16 1 8 V6F 8DM 6 12 12 12 45 0 20 3 8 V12F 8DM FLASHING INSTALLATION V6F 8DM OR V12F 8DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat aga...

Page 11: ...combination with the pipe assembly to achieve the correct chimney height Note In the rare instance there is a problem with the side driven rain or wind or the chim ney is not drafting properly an ADS...

Page 12: ...terials do not overlap the face itself Brick glass tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other o...

Page 13: ...line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping andconnections mustbetested for l...

Page 14: ...ck from the doors and never allow flames to contact the glass WARNING Fireplaces equipped with glass doors should be operated only with doorsfullyopenedordoorsfully closed Doors ifleftpartlyopen may d...

Page 15: ...moved out of place while fireplace was in transit These cover plates must be kept in the proper location prior to using the fireplace See Figure 23 For further operating guidelines instruc tions and w...

Page 16: ...laces US com 127020 01A 16 PARTS WOOD BURNING FIREPLACE MODELS WRE3036WS WRE3036WH WRE3036RS AND WRE3036RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38...

Page 17: ...ctor 1 21 111327 01 Fireplace Top Insulation 1 22 107775 01 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left Refractory Bracket 1 25 111028 01 Grate 1 26 11418 Push On Nut 2 27...

Page 18: ...actory Textured Red Herringbone 1 106659 01 Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Re...

Page 19: ...FLASHING 0 TO 6 12 PITCH V6F 8DM 6 12 TO 12 12 PITCH V12F 8DM ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM HOOD STAINLESS STEEL HS36 Required when installing a vent free gas log in this firep...

Page 20: ...D RTL 8HT MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT 8DM RTT 8HT RTTL 8DM AND RTTL 8HT ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION...

Page 21: ...cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance...

Page 22: ...rmal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Page 23: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Page 24: ...127020 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127020 01...

Page 25: ...ted by local codes WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous d...

Page 26: ...er control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous op...

Page 27: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Page 28: ...COMBUSTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STA...

Page 29: ...Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections...

Page 30: ...f Combustible Materials Fireplace Opening Non Combustible Materials Below Top Spacer Upper Section of Fireplace DRAIN PAN DP42 For outdoor installations the fireplace enclosure must allow for adequate...

Page 31: ...gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are...

Page 32: ...R 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used after elbow offset is attached 1 To achieve desired offset you may i...

Page 33: ...ntinued Figure 8 Typical Offset Installation 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR...

Page 34: ...into a living space above firestop must be placed onto ceiling from below as shown in Figure 10 They also provide complete separation from one floor space to an other or attic space as required by mo...

Page 35: ...aterial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for al...

Page 36: ...ne conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figu...

Page 37: ...lass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF B...

Page 38: ...t These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 23 For further operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or...

Page 39: ...Refractory Textured Red Herringbone 1 11 107816 03 Rear Refractory Textured White Brick 1 108171 03 Rear Refractory Textured White Herringbone 1 107816 02 Rear Refractory Textured Red Brick 1 108171...

Page 40: ...27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 39 31 7 37 38 36 28 29 24 23 15 PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS WRE3042WH WRE3042RS WRE3042RH MODEL NO CATALOG NO WRE3042...

Page 41: ...ge 15 Bottom Rear Refractory 1 13 See Page 15 Bottom Front Refractory 1 14 106683 01 Firebox Support Leg 4 15 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1 18 106703 01 Air K...

Page 42: ...SECTION RTT 8DM MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTTL 8DM ACCESSORIES DOUBLE WALL PIPE 12 8DM 12 8HT 18 8DM 18 8 HT 24 8DM 24 8HT 36 8DM 36 8HT 48 8DM 48 8HT ROOF FLASHING 0 TO 6 12 PITCH...

Page 43: ...delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions...

Page 44: ...n design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127055 01 Rev D 10...

Reviews: