NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
13
Step 1.
Follow the instructions below for the model you are installing:
Models VRT2536WS and VRT2542WS:
Using a screwdriver remove the screw from the blower access panel
as shown in
Figure 15.
Slide the panel to the right until the fl ange
clears the opening. Remove the panel and set aside.
Step 2.
Remove the rectangular knock-out (for J-Box) on the right side
of unit (see
Figure 6
for location).
Install the Junction Box and Electrical
outlet below the fi rebox fl oor into the rectangular opening on the right
side cabinet panel where you removed the knock-out (see
Figures 16
and 17
). The Junction Box / Electrical Kit is sold separately (see
Page
15
for ordering information).
• Squeeze the J-Box fl anges together to fi t into the opening shown in
Figures 17 and 18.
• Wires will need to be passed through the hole shown in Figure 16.
• An approved strain relief bushing (not supplied with the kit), is required
to restrain the wires (see Figure 16).
Step 3.
Loosely tie a knot in the power cord to take up slack (see
Figure 19
)
.
Step 4.
Locate the tabs shown in
Figure 20.
Position the blower assembly
so that the tabs (located on the cabinet base) are seated in the notches of
the blower bracket. Bend the tabs over to secure the blower assembly (see
Figure 21
)
.
Step 5.
Plug power cord into the electrical outlet as illustrated in
Figure 13
.
J-Box Flanges
J-Box and
Electrical
Outlet
Right Outside Cabinet Panel
Wires
Figure 17
Figure 15 -
Models VRT2536WS and VRT2542WS
Figure 18
IMPORTANT
All electrical wiring must be performed by licensed Elec-
tricians. Electrical wiring must comply with the National
Electrical Code ANSI/ NFPA 70 - latest edition
Installation Instructions -
FBK-100 or FBK 200 Blower Kits and JBK Junction Box Kit
Firebox
fl oor
Blower
Access
Panel
Remove screw, then lift out blower access panel.
J-Box Flange
Install into side wall rectanular opening
Firebox
fl oor
Screw
Figure 16 -
Junction Box Kit (all models)
J-Box and
Receptacle
J-Box and Electrical Outlet
Screw
Remove knock-out
(strain relief bush-
ing [not supplied]
presses into this
hole around romex
wires - see Step 8 on
Page 14).
Cover Plate